English
Language : 

TLC552C_06 Datasheet, PDF (5/10 Pages) Texas Instruments – DUAL LINCMOSE™ TIMER
TLC552C
DUAL LINCMOS™ TIMER
SLFS046 – FEBRUARY 1984 – REVISED MAY 1988
electrical characteristics at specified free-air temperature, VDD = 5 V
PARAMETER
Threshold voltage level
TEST CONDITIONS
TA†
25°C
Full range
Threshold current
25°C
MAX
Trigger voltage level
25°C
Full range
Trigger current
25°C
MAX
Reset voltage level
25°C
Full range
Reset current
25°C
MAX
Control voltage (open-circuit) as a percentage of supply voltage
MAX
Discharge switch on-state voltage
IOL = 10 mA
25°C
Full range
Discharge switch off-state current
25°C
MAX
IOL = 8 mA
25°C
Full range
Low-level output voltage
IOL = 5 mA
25°C
Full range
IOL = 3.2 mA
25°C
Full range
High-level output voltage
IOH = – 1 mA
25°C
Full range
Supply current
† Full range (MIN to MAX) is 0°C to 70°C.
25°C
Full range
MIN TYP
2.8 3.3
2.7
10
75
1.36 1.66
1.26
10
75
0.4 1.1
0.3
10
75
66.7%
0.14
0.1
0.5
0.21
0.13
0.08
4.1 4.8
4.1
340
MAX
3.8
3.9
1.96
2.06
1.5
1.8
0.5
0.6
0.4
0.5
0.3
0.4
0.3
0.35
700
1000
UNIT
V
pA
V
pA
V
pA
V
nA
V
V
µA
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5