English
Language : 

TLC552C_06 Datasheet, PDF (4/10 Pages) Texas Instruments – DUAL LINCMOSE™ TIMER
TLC552C
DUAL LINCMOS™ TIMER
SLFS046 – FEBRUARY 1984 – REVISED MAY 1988
electrical characteristics at specified free-air temperature, VDD = 2 V
PARAMETER
Threshold voltage level
TEST CONDITIONS
TA†
25°C
Full range
Threshold current
25°C
MAX
Trigger voltage level
25°C
Full range
Trigger current
25°C
MAX
Reset voltage level
25°C
Full range
Reset current
25°C
MAX
Control voltage (open-circuit) as a percentage of supply voltage
MAX
Discharge switch on-state voltage
IOL = 1 mA
25°C
Full range
Discharge switch off-state current
25°C
MAX
Low-level output voltage
IOL = 1 mA
25°C
Full range
High-level output voltage
IOH = – 300 µA
25°C
Full range
Supply current
† Full range (MIN to MAX) is 0°C to 70°C.
25°C
Full range
MIN TYP
0.95 1.33
0.85
10
75
0.4 0.67
0.3
10
75
0.4 1.1
0.3
10
75
66.7%
0.03
0.1
0.5
0.07
1.5 1.9
1.5
130
MAX
1.65
1.75
0.95
1.05
1.5
1.8
0.2
0.25
0.3
0.35
500
800
UNIT
V
pA
V
pA
V
pA
V
nA
V
V
µA
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265