English
Language : 

SN74AUC16501 Datasheet, PDF (5/13 Pages) Texas Instruments – 18-BIT UNIVERSAL BUS TRANSCEIVER WITH 3-STATE OUTPUTS
www.ti.com
SN74AUC16501
18-BIT UNIVERSAL BUS TRANSCEIVER
WITH 3-STATE OUTPUTS
SCES418 – DECEMBER 2002 – REVISED JUNE 2005
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VOH
VOL
II
Ioff
IOZ (2)
ICC
Ci
Cio
IOH = –100 µA
IOH = –0.7 mA
IOH = –3 mA
IOH = –5 mA
IOH = –8 mA
IOH = –9 mA
IOL = 100 µA
IOL = 0.7 mA
IOL = 3 mA
IOL = 5 mA
IOL = 8 mA
IOL = 9 mA
Control inputs VI = VCC or GND
VI or VO = 2.7 V
VO = VCC or GND
VI = VCC or GND,
VI = VCC or GND
VO = VCC or GND
IO = 0
VCC
0.8 V to 2.7 V
0.8 V
1.1 V
1.4 V
1.65 V
2.3 V
0.8 V to 2.7 V
0.8 V
1.1 V
1.4 V
1.65 V
2.3 V
0.8 V to 2.7 V
0
2.7 V
0.8 V to 2.7 V
2.5 V
2.5 V
MIN TYP(1) MAX
VCC – 0.1
0.55
0.8
1
1.2
1.8
0.2
0.25
0.3
0.4
0.45
0.6
±5
±10
±10
20
3.5 4.5
6 7.5
UNIT
V
V
µA
µA
µA
µA
pF
pF
(1) All typical values are at TA = 25°C.
(2) For I/O ports, the parameter IOZ includes the input leakage current.
Timing Requirements
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
fclock
tw
tsu
th
Clock frequency
Pulse
LE high
duration CLK high or low
Setup
time
Data before CLK↑
CLK high
Data before LE↓
CLK low
Data after CLK↑
Hold time
Data after LE↓
CLK high
or low
VCC = 0.8 V
TYP
85
5.8
5.8
0.2
0.1
0.1
0.3
VCC = 1.2 V VCC = 1.5 V VCC = 1.8 V VCC = 2.5 V
± 0.1 V
± 0.1 V
± 0.15 V
± 0.2 V
MIN MAX MIN MAX MIN MAX MIN MAX
150
250
300
350
4
1.7
1.5
1.5
4
1.7
1.5
1.5
0.6
0.6
0.6
0.6
0.4
0.4
0.3
0.3
0.4
0.4
0.3
0.3
1.2
1.1
0.9
0.9
1.3
1.5
1.3
1.2
1.2
UNIT
MHz
ns
ns
ns
5