English
Language : 

CLV4051ATDWRG4Q1 Datasheet, PDF (5/18 Pages) Texas Instruments – 8-CHANNEL ANALOG MULTIPLEXER/DEMULTIPLEXER
SN74LV4051A-Q1
www.ti.com
SCLS520D – AUGUST 2003 – REVISED JUNE 2011
SWITCHING CHARACTERISTICS
VCC = 3.3 V ± 0.3 V, over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST
CONDITIONS
TA = 25°C
MIN TYP MAX
TA = -40 to
105°C
MIN MAX
TA = -40 to
125°C
MIN MAX
tPLH Propagation
tPHL delay time
COM or Yn Yn or COM
CL = 50 pF
(see Figure 4)
2.5
9
12
14
tPZH Enable delay
tPZL time
INH
COM or Yn
CL = 50 pF
(see Figure 5)
5.5 20
25
25
tPHZ Disable delay
tPLZ time
INH
COM or Yn
CL = 50 pF
(see Figure 5)
8.8 20
25
25
UNIT
ns
ns
ns
SWITCHING CHARACTERISTICS
VCC = 5 V ± 0.5 V, over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST
CONDITIONS
TA = 25°C
MIN TYP MAX
TA = -40 to
105°C
MIN
MAX
TA = -40 to
125°C
MIN
MAX
tPLH Propagation
tPHL delay time
COM or Yn
Yn or COM
CL = 50 pF
(see Figure 4)
1.5 6
8
10
tPZH Enable delay
tPZL time
INH
COM or Yn
CL = 50 pF
(see Figure 5)
4 14
18
18
tPHZ Disable delay
tPLZ time
INH
COM or Yn
CL = 50 pF
(see Figure 5)
6.2 14
18
18
UNIT
ns
ns
ns
ANALOG SWITCH CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
TEST CONDITIONS
VCC
Frequency response
(switch on)
COM or Yn
Crosstalk
(control input to signal
INH
output)
Feedthrough
attenuation
(switch off)
COM or Yn
Sine-wave distortion
COM or Yn
Yn or COM
COM or Yn
Yn or COM
Yn or COM
CL = 50 pF,
RL = 600 Ω,
fin = 1 MHz (sine wave)(1)
(see Figure 6)
CL = 50 pF,
RL = 600 Ω,
fin = 1 MHz (square wave)
(seeFigure 7 )
CL = 50 pF,
RL = 600 Ω,
fin = 1 MHz(2)
(see Figure 8)
CL = 50 pF,
RL = 10 kΩ,
fin = 1 kkHz (sine
wave)
(see Figure 9)
VI = 2 Vp-p
VI = 2.5 Vp-p
VI = 4 Vp-p
2.3 V
3V
4.5 V
2.3 V
3V
4.5 V
2.3 V
3V
4.5 V
2.3 V
3V
4.5 V
(1) Adjust fin voltage to obtain 0-dBm output. Increase fin frequency until dB meter reads −3 dB.
(2) Adjust fin voltage to obtain 0-dBm input.
TA = 25°C
MIN TYP
20
25
35
20
35
60
–45
–45
–45
0.1
0.1
0.1
MAX
UNIT
MHz
mV
dB
%
OPERATING CHARACTERISTICS
VCC = 3.3 V, TA = 25°C (unless otherwise noted)
PARAMETER
Cpd Power dissipation capacitance
TEST CONDITIONS
CL = 50 pF, f = 10 MHz
TYP UNIT
5.9 pF
Copyright © 2003–2011, Texas Instruments Incorporated
5