A
1T/C
1Y1
tPLH1
1Y2
tPLH2
2T/C
CDC329
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCBS117A–D4501, JANUARY 1991–REVISED NOVEMBER 1992
WAVEFORMS FOR CALCULATION OF tsk(o)
tPHL1
tPHL2
tPLH5
tPLH6
tPHL5
tPHL6
2Y1
tPLH3
tPHL3
tPHL7
tPLH7
2Y2
tPLH4
tPHL4
tPHL8
tPLH8
Output skew, tsk(o), from A to any Y (same phase), can be measured only between outputs for which the respective polarity control inputs (T/C)
are at the same logic level. It is calculated as the greater of:
a) the difference between the fastest and slowest of tPLH from A↑ to any Y
(e.g., tPLHn, n = 1 to 4; or tPLHn, n = 5 to 6),
b) the difference between the fastest and slowest of tPHL from A↓ to any Y
(e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6),
c) the difference between the fastest and slowest of tPLH from A↓ to any Y
(e.g., tPLHn, n = 7 to 8), and
d) the difference between the fastest and slowest of tPHL from A↑ to any Y
(e.g., tPHLn, n = 7 to 8).
Output skew, tsk(o), from A to any Y (any phase), can be measured between outputs for which the respective polarity control inputs (T/C) are at
the same or different logic levels. It is calculated as the greater of:
a) the difference between the fastest and slowest of tPLH from A↑ to any Y or tPHL from A↑ to any Y
(e.g., tPLHn, n = 1 to 4; or tPLHn, n = 5 to 6, and tPHLn, n = 7 to 8), and
b) the difference between the fastest and slowest of tPHL from A↓ to any Y or tPLH from A↓ to any Y
(e.g., tPHLn, n = 1 to 4; or tPHLn, n = 5 to 6, and tPLHn, n = 7 to 8).
Figure 2. Skew Waveforms and Calculations