CDC329 Datasheet, PDF (2/6 Pages) Texas Instruments – 1-LINE TO 6-LINE CLOCK DRIVER WITH SELECTABLE POLARITY | |||
|
◁ |
CDC329
1-LINE TO 6-LINE CLOCK DRIVER
WITH SELECTABLE POLARITY
SCBS117AâD4501, JANUARY 1991âREVISED NOVEMBER 1992
logic diagram (positive logic)
15
1T/C
13
2T/C
12
A
10
3T/C
9
4T/C
16
1Y1
2
1Y2
3
2Y1
5
2Y2
6
3Y
8
4Y
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)â
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â1.2 V to 7 V
Voltage range applied to any output in the high state
or power-off state, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â 0.5 V to VCC + 0.5 V
Current into any output in the low state, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA
Input clamp current, IIK (VI < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â18 mA
Output clamp current, IOK (VO < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â 50 mA
Continuous total power dissipation at (or below) 25°C free-air temperature (see Note 2) . . . . . . . . 1000 mW
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â 65°C to 150°C
â Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating conditionsâ is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. For operation above 25°C free-air temperature, derate to 478 mW at 85°C at the rate of 8.7 mW/°C.
recommended operating conditions (see Note 3)
VCC
VIH
VIL
VI
IOH
IOL
ât / âv
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
High-level output current
Low-level output current
Input transition rise or fall rate
TA
Operating free-air temperature
NOTE 3: Unused inputs must be held high or low.
MIN NOM MAX UNIT
4.75
5 5.25 V
2
V
0.8 V
0
VCC V
â15 mA
64 mA
5 ns / V
â 40
85 °C
2