3.3 DISSIPATION RATINGS
PACKAGE
12-pin DRZ(1)
TA ≤ 40°C
POWER RATING
482 mW
DERATING FACTOR
TA > 40°C
5.67 mW/°C
RθJA
176°C/W
(1) This data is based on using a four-layer JEDEC high-K board with the exposed die pad connected to a Cu pad on the board. The board
pad is connected to the ground plane by a 2- × 2-via matrix.
3.4 POWER-ON RESET
TA = –40°C to 85°C, typical values at TA = 25°C and VBAT = 3.6 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
VIT+
VHYS
Positive-going battery voltage input at VCC
Hysteresis voltage
2.09
45
TYP MAX UNIT
2.2 2.31 V
115
185 mV
3.5 INTERNAL TEMPERATURE SENSOR CHARACTERISTICS
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
GTEMP
Temperature sensor voltage gain
–2
UNIT
mV/°C
3.6 HIGH-FREQUENCY OSCILLATOR
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
fOSC
fEIO
tSXO
Operating frequency
Frequency error(1) (2)
Start-up time(3)
TA = 0°C to 60°C
TA = –20°C to 70°C
TA = –40°C to 85°C
2.097
–2% 0.38%
–3% 0.38%
–4.5% 0.38%
2.5
2%
3%
4.5%
5
MHz
ms
(1) The frequency error is measured from 2.097 MHz.
(2) The frequency drift is included and measured from the trimmed frequency at VCC = 2.5 V, TA = 25°C.
(3) The start-up time is defined as the time it takes for the oscillator output frequency to be within ±3% of typical oscillator frequency.
3.7 LOW-FREQUENCY OSCILLATOR
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
fLOSC
fLEIO
tLSXO
Operating frequency
Frequency error(1) (2)
Start-up time(3)
TA = 0°C to 60°C
TA = –20°C to 70°C
TA = –40°C to 85°C
–1.5%
–2.5%
–4%
32.768
0.25%
0.25%
0.25%
kHz
1.5%
2.5%
4%
500 µs
(1) The frequency drift is included and measured from the trimmed frequency at VCC = 2.5 V, TA = 25°C.
(2) The frequency error is measured from 32.768 kHz.
(3) The start-up time is defined as the time it takes for the oscillator output frequency to be within ±3% of typical oscillator frequency.
Submit Documentation Feedback
ELECTRICAL SPECIFICATIONS