English
Language : 

TLC220X_08 Datasheet, PDF (42/64 Pages) Texas Instruments – Advanced LinCMOSE LOW-NOISE PRECISION OPERATIONAL AMPLIFIERS
TLC220x, TLC220xA, TLC220xB, TLC220xY
Advanced LinCMOS™ LOW-NOISE PRECISION
OPERATIONAL AMPLIFIERS
SLOS175 – FEBRUARY 1997
PARAMETER MEASUREMENT INFORMATION
20 Ω
2 kΩ
VDD +
–
+
VO
VDD – /GND
20 Ω
Figure 1. Noise-Voltage Test Circuit
VI
100 Ω
10 kΩ
VDD +
–
+
VDD –
CL
(see Note A)
VO
RL
NOTE A: CL includes fixture capacitance.
Figure 2. Phase-Margin Test Circuit
VDD +
–
VI
+
VDD –
CL
(see Note A)
VO
RL
Ground Shield VDD +
–
+
VO
pA pA
VDD – /GND
NOTE A: CL includes fixture capacitance.
Figure 3. Slew-Rate Test Circuit
Figure 4. Input-Bias and Offset-Current Test Circuit
typical values
Typical values presented in this data sheet represent the median (50% point) of device parametric performance.
input bias and offset current
At the picoamp bias current level of the TLC220x, TLC220xA, and TLC220xB, accurate measurement of the
bias current becomes difficult. Not only does this measurement require a picoammeter, but test socket leakages
can easily exceed the actual device bias currents. To measure these small currents, Texas Instruments uses
a two-step process. The socket leakage is measured using picoammeters with bias voltages applied but with
no device in the socket. The device is then inserted in the socket, and a second test measuring both the socket
leakage and the device input bias current is performed. The two measurements are then subtracted
algebraically to determine the bias current of the device.
noise
Texas Instruments offers automated production noise testing to meet individual application requirements. Noise
voltage at f = 10 Hz and f = 1 kHz is 100% tested on every TLC2201B device, while lot sample testing is
performed on the TLC220xA. For other noise requirements, please contact the factory.
42
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265