English
Language : 

TLC220X_08 Datasheet, PDF (22/64 Pages) Texas Instruments – Advanced LinCMOSE LOW-NOISE PRECISION OPERATIONAL AMPLIFIERS
TLC220x, TLC220xA, TLC220xB, TLC220xY
Advanced LinCMOS™ LOW-NOISE PRECISION
OPERATIONAL AMPLIFIERS
SLOS175 – FEBRUARY 1997
TLC2201I electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
VIO Input offset voltage
TEST CONDITIONS
TA†
25°C
Full range
TLC2201AI
MIN TYP MAX
80 200
350
TLC2201BI
MIN TYP MAX
80 200
350
UNIT
µA
αVIO
Temperature coefficient of
input offset voltage
Full range
0.5
0.5
µV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.001 0.005
0.001 0.005 µV/mo
IIO
Input offset current
IIB
Input bias current
25°C
Full range
25°C
Full range
0.5
150
1
150
0.5
pA
150
1
pA
150
VICR
Common-mode input voltage
range
RS = 50 Ω
0
Full range
to
2.7
0
to
2.7
V
VOH
Maximum high-level output
voltage
RL = 10 kΩ
25°C
4.7 4.8
4.7 4.8
V
Full range 4.7
4.7
VOL
Maximum low-level output
voltage
IO = 0
25°C
Full range
0 50
50
0 50
mV
50
AVD
Large-signal differential
voltage amplification
VO = 1 V to 4 V,
RL = 500 kΩ
VO = 1 V to 4 V,
RL = 10 kΩ
25°C
150 315
Full range 100
25°C
25 55
Full range 15
150 315
100
25 55
15
V/mV
CMRR Common-mode rejection ratio
kSVR
Supply voltage rejection ratio
(∆VDD ± /∆VIO)
VIC = VICRmin,
VO = 0,
RS = 50 Ω
VDD = 4.6 V to 16 V
25°C
Full range
25°C
Full range
90 110
85
90 110
85
90 110
dB
85
90 110
dB
85
IDD Supply current
VO = 2.5 V, No load
25°C
Full range
1 1.5
1.5
1 1.5
mA
1.5
† Full range is – 40°C to 85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
22
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265