www.ti.com
CONFIG1: Configuration Register 1
Address = 01h
BIT 7
0
BIT 6
DAISY_EN
BIT 5
CLK_EN
BIT 4
0
SBAS471C – APRIL 2010 – REVISED NOVEMBER 2011
BIT 3
0
BIT 2
DR2
BIT 1
DR1
BIT 0
DR0
Bit 7
Bit 6
Bit 5
Bits[4:3]
Bits[2:0]
Must always be set to '0'
DAISY_EN: Daisy-chain/multiple readback mode
This bit determines which mode is enabled.
0 = Daisy-chain mode (default)
1 = Multiple readback mode
CLK_EN: CLK connection(1)
This bit determines if the internal oscillator signal is connected to the CLK pin when the CLKSEL pin = 1.
0 = Oscillator clock output disabled (default)
1 = Oscillator clock output enabled
Must always be set to '0'
DR[2:0]: Output data rate.
fMOD = fCLK/16.
These bits determine the output data rate of the device.
(1) Additional power will be consumed when driving external devices.
BIT
000
001
010
011
100 (default)
101
110
111
(1) fCLK = 2.048MHz.
DATA RATE
fMOD/16
fMOD/32
fMOD/64
fMOD/128
fMOD/256
fMOD/512
fMOD/1024
DO NOT USE
SAMPLE RATE(1)
8kSPS
4kSPS
2kSPS
1kSPS
500SPS
250SPS
125SPS
N/A
Copyright © 2010–2011, Texas Instruments Incorporated