TLE206X_07 Datasheet, PDF (40/78 Pages) Texas Instruments – EXCALIBUR JFET-INPUT HIGH-OUTPUT-DRIVE uPOWER OPERATIONAL AMPLIFIERS | |||
|
◁ |
TLE206x, TLE206xA, TLE206xB
Ä
EXCALIBUR JFETÄINPUT HIGHÄOUTPUTÄDRIVE
µPOWER OPERATIONAL AMPLIFIERS
SLOS193B â FEBRUARY 1997 â REVISED MAY 2004
TLE2064M electrical characteristics at specified free-air temperature, VCC± = ±5 V (unless
otherwise noted)
PARAMETER
TLE2064M
TLE2064AM
TEST CONDITIONS
TAâ
TLE2064BM
UNIT
MIN TYP MAX
TLE2064M
25°C
Full range
1.2
7
9
VIO
Input offset voltage
TLE2064AM
25°C
Full range
1.2
6
mV
8
αVIO
TLE2064BM
Temperature coefficient of input offset voltage VIC = 0,
Input offset voltage long-term drift (see Note 4)
RS = 50 â¦
25°C
Full range
25°C
Full range
0.8
3.5
5.5
6
µV/°C
0.04
µV/mo
IIO
Input offset current
25°C
Full range
1
pA
15 nA
IIB
Input bias current
25°C
Full range
3
pA
30 nA
VICR Common-mode input voltage range
â1.6 â2
25°C
to to
V
46
â 1.6
Full range
to
V
4
RL = 10 kâ¦
25°C
Full range
3.5 3.7
3
Maximum positive peak output FK and J
VOM + voltage swing
packages
RL = 600 â¦
25°C
2.5 3.6
V
Full range
2
D and N
packages
RL = 100 â¦
25°C
Full range
2.5 3.1
2
RL = 10 kâ¦
25°C
Full range
â3.5 â3.9
â3
Maximum negative peak output FK and J
VOM â voltage swing
packages
RL = 600 â¦
25°C
â2.5 â3.5
V
Full range
â2
D and N
packages
RL = 100 â¦
25°C
Full range
â2.5 â2.7
â2
VO = ± 2.8 V,
25°C
RL = 10 k⦠Full range
15 80
2
A VD
Large-signal differential voltage
amplification
FK and J
25°C
VO = 0 to 2.5 V, RL = 600 ⦠Full range
1 65
0.5
V/mV
packages
25°C
VO = 0 to â 2.5 V, RL = 600 ⦠Full range
1 16
0.5
â Full range is â 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
40