English
Language : 

TLC555-Q1 Datasheet, PDF (4/13 Pages) Texas Instruments – LinCMOS™ TIMER
TLC555-Q1
LinCMOS™ TIMER
SLFS078 – OCTOBER 2006
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
www.ti.com
VDD
Supply voltage(2)
VI
Input voltage range
Sink current, discharge or output
IO
Source current, output
Continuous total power dissipation
TA
Operating free-air temperature range
Tstg
Storage temperature range
Lead temperature
HBM (Human Body Model) ESD
Any input
1,6 mm (1/16 ch) from case for 10 s
MIN
MAX
18
–0.3
VDD
150
15
See Dissipation
Rating Table
–40
125
–65
150
260
1000
UNIT
V
V
mA
mA
°C
°C
°C
V
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to network GND.
Dissipation Ratings
PACKAGE
D
TA ≤ 25°C
POWER RATING
725 mW
DERATING FACTOR
ABOVE TA = 25°C
5.8 mW/°C
TA = 125°C
POWER RATING
145 mW
Recommended Operating Conditions
VDD
Supply voltage
TA
Operating free-air temperature
MIN
MAX UNIT
2
15 V
–40
125 °C
4
Submit Documentation Feedback