English
Language : 

TLC352 Datasheet, PDF (4/9 Pages) Texas Instruments – LinCMOSE DUAL DIFFERENTIAL COMPARATOR
recommended operating conditions
Supply voltage, VDD
Common-mode input voltage, VIC
Operating free-air temperature, TA
VDD = 5 V
VDD = 10 V
TLC352C
MIN MAX
1.4
16
0 3.5
0 8.5
0
70
TLC352I
MIN MAX
1.4
16
0 3.5
0 8.5
– 40
85
TLC352M
MIN MAX
1.4
16
0 3.5
0 8.5
– 55 125
UNIT
V
V
°C
electrical characteristics at specified free-air temperature, VDD = 1.4 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLC352C
MIN TYP MAX
TLC352I
MIN TYP MAX
TLC352M
MIN TYP MAX
UNIT
VIO Input offset voltage
VIC = VICR min, See Note 4
25°C
Full range
2
5
6.5
2
5
7
2
5
mV
10
IIO Input offset current
25°C
MAX
1
0.3
1
1
1
pA
10 nA
IIB
Input bias current
25°C
MAX
5
0.6
5
2
5
pA
20 nA
VICR
Common-mode input voltage
range
Full range
0 to
0.2
0 to
0.2
0 to
0.2
V
VOL Low-level output voltage
25°C
Full range
100 200
200
100 200
200
100 200
mV
200
IOL Low-level output current
VID = – 0.5 V, VOL = 0.3 V
25°C
1
1.6
1
1.6
1
1.6
mA
IDD Supply current (two comparators) VID = 0.5 V,
No load
25°C
Full range
65 150
200
65 150
200
65 150
µA
200
† All characteristics are measured with zero common-mode input voltage unless otherwise noted. Full range is 0°C to 70°C for TLC352C, – 40°C to 85°C for TLC352I, – 55°C to 125°C
for TLC352M. IMPORTANT: See Parameter Measurement Information.
NOTE 4: The offset voltage limits given are the maximum values required to drive the output above 1.25 V or below 150 mV with a 10-kΩ resistor between the output and VDD. They
can be verified by applying the limit value to the input and checking for the appropriate output state.