absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 V
Differential input voltage range, VID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± VDD
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA: C suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
I suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 125°C
Maximum junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential voltages, are with respect to GND .
PACKAGE
D (8)
D (14)
D (16)
DGN (8)
DGQ (10)
N (14, 16)
P (8)
PWP (20)
DISSIPATION RATING TABLE
θJC
(°C/W)
θJA
(°C/W)
38.3
176
26.9
122.3
25.7
114.7
4.7
52.7
4.7
52.3
32
78
41
104
1.40
26.1
TA ≤ 25°C
POWER RATING
710 mW
1022 mW
1090 mW
2.37 W
2.39 W
1600 mW
1200 mW
4.79 W
recommended operating conditions
Supply voltage, VDD
Common-mode input voltage, VICR
Shutdown on/off voltage level‡
Operating free-air temperature, TA
‡ Relative to the voltage on the GND terminal of the device.
Single supply
Split supply
VIH
VOL
C-suffix
I-suffix
MIN
4.5
±2.25
+0.5
2
0
− 40
MAX
16
±8
VDD−0.8
UNIT
V
V
V
0.8
70
°C
125
4