English
Language : 

TL497AC Datasheet, PDF (4/11 Pages) Texas Instruments – SWITCHING VOLTAGE REGULATORS
TL497AC, TL497AI, TL497AY
SWITCHING VOLTAGE REGULATORS
SLVS009C – JUNE 1976 – REVISED AUGUST 1995
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 V
Output voltage, VO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
Input voltage, VI(COMP INPUT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 V
Input voltage, VI (INHIBIT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 V
Diode reverse voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
Power switch current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750 mA
Diode forward current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750 mA
Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA: TL497AC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TL497AI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values except diode voltages are with respect to network ground terminal.
PACKAGE
D
N
PW
TA ≤ 25°C
POWER RATING
950 mW
1000 mW
700 mW
DISSIPATION RATING TABLE
DERATING
FACTOR
7.6 mW/°C
DERATE
ABOVE TA
25°C
9.2 mW/°C
41°C
5.6 mW/°C
25°C
TA = 70°C
POWER RATING
608 mW
733 mW
448 mW
TA = 85°C
POWER RATING
494 mW
595 mW
—
recommended operating conditions
Supply voltage, VCC
High-level input voltage, VIH, INHIBIT
Low-level input voltage, VIL, INHIBIT
Step-up configuration (see Figure 1)
Output voltage Step-down configuration (see Figure 2)
Inverting regulator (see Figure 3)
Power switch current
Diode forward current
Operating free-air temperature, TA
TL497AC
TL497AI
MIN
4.5
2.5
VI + 2
Vref
–Vref
0
– 40
MAX
12
0.8
30
VI – 1
– 25
500
500
70
85
UNIT
V
V
V
V
mA
mA
°C
4–4