OPAMP1, Operational Amplifier With Noninverting Input Connected to the Internal VREF
Electrical Characteristics
VCC+ = 5 V, VCC = GND, TA = 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TL103W
Vicm = 0 V
VIO
Input offset voltage
TL103WA Vicm = 0 V
TA
25°C
Full range
25°C
Full range
MIN TYP MAX
1
4
5
0.5
3
5
αVIO
IIB
AVD
kSVR
Isource
ISC
Isink
VOH
Input offset-voltage drift
Input bias current (negative input)
Large-signal voltage gain
Supply-voltage rejection ratio
Output source current
Short circuit to GND
Output sink current
High-level output voltage
VCC+ = 15 V, RL = 2 kΩ, Vicm = 0 V
VCC+ = 5 V to 30 V, Vicm = 0 V
VCC+ = 15 V, VO = 2 V, Vid = 1 V
VCC+ = 15 V
VCC+ = 15 V, VO = 2 V, Vid = –1 V
VCC+ = 15 V, VO = 0.2 V, Vid = –1 V
VCC = 30 V, RL = 2 kΩ
VCC = 30 V, RL = 10 kΩ
25°C
25°C
25°C
25°C
25°C
25°C
25°C
25°C
Full range
25°C
Full range
7
20
100
65 100
20
40
40
60
10
12
12
50
26
27
26
27
28
27
VOL
Low-level output voltage
RL = 10 kΩ
25°C
Full range
5
20
20
SR
GBW
THD
Slew rate at unity gain
Gain bandwidth product
Total harmonic distortion
VCC+ = 15 V, CL = 100 pF,
RL = 2 kΩ, VI = 0.5 V to 2 V, unity gain
VCC+ = 30 V, VI = 10 mV,
CL = 100 pF, RL = 2 kΩ, f = 100 kHz
VCC+ = 30 V, VO = 2 Vpp, CL = 100 pF,
RL = 2 kΩ, f = 1 kHz, AV = 20 dB
25°C
25°C
25°C
0.2 0.4
0.5 0.9
0.02
UNIT
mV
µV/°C
nA
V/mV
dB
mA
mA
mA
µA
V
mV
V/µs
MHz
%
4