|
THS4508 Datasheet, PDF (4/29 Pages) Texas Instruments – WIDEBAND, LOW NOISE, LOW DISTORTION FULLY DIFFERENTIAL AMPLIFIER | |||
|
◁ |
THS4508
SLAS459A â SEPTEMBER 2005 â REVISED FEBRUARY 2006
www.ti.com
ELECTRICAL CHARACTERISTICS; VS+â VSâ = 5 V:
Test conditions unless otherwise noted: VS+ = 5 V, VSâ = 0 V, G = 10 dB, CM = open, VO = 2 Vpp, RF = 349 â¦, RL = 200 â¦
Differential, T = 25°C Single-Ended Input, Differential Output, Input Referenced to Ground, and Output Referenced to
Mid-supply
PARAMETER
AC PERFORMANCE (Figure 44)
Small-Signal Bandwidth
Gain-Bandwidth Product
Bandwidth for 0.1dB flatness
Large-Signal Bandwidth
Slew Rate (Differential)
Rise Time
Fall Time
Settling Time to 0.1%
2nd Order Harmonic Distortion
3rd Order Harmonic Distortion
2nd Order Intermodulation Distortion
3rd Order Intermodulation Distortion
2nd Order Output Intercept Point
3rd Order Output Intercept Point
1-dB Compression Point(2)
Noise Figure
Input Voltage Noise
Input Current Noise
DC PERFORMANCE
Open-Loop Voltage Gain (AOL)
Input Offset Voltage
Average Offset Voltage Drift
Input Bias Current
Average Bias Current Drift
Input Offset Current
Average Offset Current Drift
TEST CONDITIONS
G = 6 dB, VO = 100 mVPP
G = 10 dB, VO = 100 mVPP
G = 14 dB, VO = 100 mVPP
G = 20 dB, VO = 100 mVPP
G = 20 dB
G = 10 dB, VO = 2 VPP
G = 10 dB, VO = 2 VPP
VO = 2-V Step
f = 10 MHz
f = 50 MHz
f = 100 MHz
f = 10 MHz
f = 50 MHz
f = 100 MHz
200 kHz tone spacing,
RL = 499 â¦
200 kHz tone spacing,
RL = 100 â¦
fC = 70 MHz
fC = 140 MHz
50-⦠system, 10 MHz
f > 10 MHz
f > 10 MHz
fC = 70 MHz
fC = 140 MHz
fC = 70 MHz
fC = 140 MHz
fC = 70 MHz
fC = 140 MHz
fC = 70 MHz
fC = 140 MHz
TA = 25°C
TA = -40°C to 85°C
TA = 25°C
TA = -40°C to 85°C
TA = 25°C
TA = -40°C to 85°C
MIN
TYP
MAX
UNITS
TEST
LEVEL (1)
2
1.7
600
300
3
400
1.5
6400
0.5
0.5
2
â104
â82
â69
â105
â92
â81
â78
â64
â95
â78
78
58
42
35
12.2
10.8
19.2
2.3
2.9
GHz
GHz
MHz
MHz
GHz
MHz
GHz
V/µs
ns
ns
ns
dBc
C
dBc
dBm
dBm
dB
nV/âHz
pA/âHz
68
dB
C
1
4
mV
A
1
5
2.3
µA/°C
B
1.75
8
15.5
µA
A
8
18.5
20
nA/°C
B
0.5
3.6
µA
A
0.5
7
7
nA/°C
B
(1) Test levels: (A) 100% tested at 25°C. Overtemperature limits by characterization and simulation. (B) Limits set by characterization and
simulation. (C) Typical value only for information.
(2) The 1-dB compression point is measured at the load with 50-⦠double termination. Add 3 dB to refer to amplifier output.
4
Submit Documentation Feedback
|
▷ |