English
Language : 

TAS5142 Datasheet, PDF (4/26 Pages) Texas Instruments – STEREO DIGITAL AMPLIFIER POWER STAGE
TAS5142
SLES126B – DECEMBER 2004 – REVISED MAY 2005
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range unless otherwise noted (1)
TAS5142
VDD to AGND
GVDD_X to AGND
PVDD_X to GND_X (2)
OUT_X to GND_X (2)
BST_X to GND_X (2)
VREG to AGND
GND_X to GND
GND_X to AGND
GND to AGND
PWM_X, OC_ADJ, M1, M2, M3 to AGND
RESET_X, SD, OTW to AGND
Maximum continuous sink current (SD, OTW)
Maximum operating junction temperature range, TJ
Storage temperature
Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds
Minimum pulse duration, low
www.ti.com
–0.3 V to 13.2 V
–0.3 V to 13.2 V
–0.3 V to 50 V
–0.3 V to 50 V
–0.3 V to 63.2 V
–0.3 V to 4.2 V
–0.3 V to 0.3 V
–0.3 V to 0.3 V
–0.3 V to 0.3 V
–0.3 V to 4.2 V
–0.3 V to 7 V
9 mA
0°C to 125°C
–40°C to 125°C
260°C
50 ns
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) These voltages represent the dc voltage + peak ac waveform measured at the terminal of the device in all conditions.
TA
0°C to 70°C
0°C to 70°C
ORDERING INFORMATION
PACKAGE
TAS5146DKD
TAS5142DDV
DESCRIPTION
36-pin PSOP3
44-pin HTSSOP
For the most current specification and package information, see the TI Web site at www.ti.com.
4