English
Language : 

SN74AUC04 Datasheet, PDF (4/7 Pages) Texas Instruments – HEX INVERTER
SN74AUC04
HEX INVERTER
SCES444 – JUNE 2003 – REVISED JUNE 2005
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
CL
(see Note A)
RL
RL
LOAD CIRCUIT
2 × VCC
S1
Open
GND
TEST
tPLH/tPHL
tPLZ/tPZL
tPHZ/tPZH
VCC
0.8 V
1.2 V ± 0.1 V
1.5 V ± 0.1 V
1.8 V ± 0.15 V
2.5 V ± 0.2 V
1.8 V ± 0.15 V
2.5 V ± 0.2 V
CL
15 pF
15 pF
15 pF
15 pF
15 pF
30 pF
30 pF
S1
Open
2 × VCC
GND
RL
2 kΩ
2 kΩ
2 kΩ
2 kΩ
2 kΩ
1 kΩ
500 Ω
www.ti.com
V∆
0.1 V
0.1 V
0.1 V
0.15 V
0.15 V
0.15 V
0.15 V
Input
Timing Input
tw
VCC/2
VCC/2
VCC
0V
VOLTAGE WAVEFORMS
PULSE DURATION
Data Input
VCC
VCC/2
0V
tsu
th
VCC/2
VCC
VCC/2
0V
VOLTAGE WAVEFORMS
SETUP AND HOLD TIMES
Input
VCC/2
VCC
VCC/2
0V
tPLH
Output
VCC/2
tPHL
VCC/2
VOH
VOL
tPHL
tPLH
Output
VCC/2
VCC/2
VOH
VOL
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
INVERTING AND NONINVERTING OUTPUTS
Output
Control
VCC/2
VCC/2
tPZL
Output
Waveform 1
S1 at 2 × VCC
(see Note B)
VCC/2
tPLZ
VOL + V∆
tPZH
Output
Waveform 2
S1 at GND
(see Note B)
VCC/2
tPHZ
VOH − V∆
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
LOW- AND HIGH-LEVEL ENABLING
VCC
0V
VCC
VOL
VOH
≈0 V
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low, except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high, except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, slew rate ≥ 1 V/ns.
D. The outputs are measured one at a time, with one transition per measurement.
E. tPLZ and tPHZ are the same as tdis.
F. tPZL and tPZH are the same as ten.
G. tPLH and tPHL are the same as tpd.
H. All parameters and waveforms are not applicable to all devices.
Figure 1. Load Circuit and Voltage Waveforms
4