English
Language : 

SN74AUC04 Datasheet, PDF (3/7 Pages) Texas Instruments – HEX INVERTER
www.ti.com
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VOH
VOL
II
A inputs
Ioff
ICC
Ci
TEST CONDITIONS
IOH = –100 µA
IOH = –0.7 mA
IOH = –3 mA
IOH = –5 mA
IOH = –8 mA
IOH = –9 mA
IOL = 100 µA
IOL = 0.7 mA
IOL = 3 mA
IOL = 5 mA
IOL = 8 mA
IOL = 9 mA
VI = VCC or GND
VI or VO = 2.7 V
VI = VCC or GND,
IO = 0
VI = VCC or GND
VCC
0.8 V to 2.7 V
0.8 V
1.1 V
1.4 V
1.65 V
2.3 V
0.8 V to 2.7 V
0.8 V
1.1 V
1.4 V
1.65 V
2.3 V
0 to 2.7 V
0
0.8 V to 2.7 V
2.5 V
(1) All typical values are at TA = 25°C.
SN74AUC04
HEX INVERTER
SCES444 – JUNE 2003 – REVISED JUNE 2005
MIN
VCC – 0.1
0.8
1
1.2
1.8
TYP(1) MAX
0.55
0.2
0.25
0.3
0.4
0.45
0.6
±5
±10
10
2.5
UNIT
V
V
µA
µA
µA
pF
Switching Characteristics
over recommended operating free-air temperature range, CL = 15 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 0.8 V
TYP
VCC = 1.2 V VCC = 1.5 V
± 0.1 V
± 0.1 V
MIN MAX MIN MAX
VCC = 1.8 V
± 0.15 V
VCC = 2.5 V
± 0.2 V
MIN TYP MAX MIN MAX
tpd
A
Y
4.8
0.7 3.3 0.5 2.9 0.5 0.8 1.5 0.4
1
UNIT
ns
Switching Characteristics
over recommended operating free-air temperature range, CL = 30 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
VCC = 1.8 V
± 0.15 V
MIN TYP MAX
VCC = 2.5 V
± 0.2 V
MIN MAX
tpd
A
Y
0.6 1.4 2.5 0.5
2
UNIT
ns
Operating Characteristics
TA = 25°C
PARAMETER
TEST
CONDITIONS
Cpd
Power dissipation
capacitance
f = 10 MHz
VCC = 0.8 V VCC = 1.2 V VCC = 1.5 V VCC = 1.8 V VCC = 2.5 V
TYP
TYP
TYP
TYP
TYP
16
17
17
17
19
UNIT
pF
3