English
Language : 

JM38510-10304BGA Datasheet, PDF (4/22 Pages) Texas Instruments – LM111JAN Voltage Comparator
LM111JAN
SNOSAM9B – JULY 2008 – REVISED MARCH 2013
Recommended Operating Conditions
Supply Voltage
Operating Temperature Range
Quality Conformance Inspection
Mil-Std-883, Method 5005 — Group A
Subgroup
1
2
3
4
5
6
7
8A
8B
9
10
11
Description
Static tests at
Static tests at
Static tests at
Dynamic tests at
Dynamic tests at
Dynamic tests at
Functional tests at
Functional tests at
Functional tests at
Switching tests at
Switching tests at
Switching tests at
LM111 JAN Electrical Characteristics DC Parameters
The following conditions apply, unless otherwise specified.
DC: VCC = ±15V, VCM = 0
Symbol
Parameter
Conditions
VIO
Input Offset Voltage
VI = 0V, RS = 50Ω
VIO R
Raised Input Offset Voltage
+VCC = 29.5V, -VCC = -0.5V,
VI = 0V, VCM = -14.5V,
RS = 50Ω
+VCC = 2V, -VCC = -28V,
VI = 0V, VCM = +13V,
RS = 50Ω
+VCC = +2.5V, -VCC = -2.5V,
VI = 0V, RS = 50Ω
VI = 0V, RS = 50Ω
IIO
Input Offset Current
+VCC = 29.5V, -VCC = -0.5V,
VI = 0V, VCM = -14.5V,
RS = 50Ω
+VCC = 2V, -VCC = -28V,
VI = 0V, VCM = +13V,
RS = 50Ω
VI = 0V, RS = 50KΩ
+VCC = 29.5V, -VCC = -0.5V,
VI = 0V, VCM = -14.5V,
RS = 50KΩ
+VCC = 2V, -VCC = -28V,
VI = 0V, VCM = +13V,
RS = 50KΩ
VCC = ±15VDC
-55°C ≤ TA ≤ 125°C
www.ti.com
Temperature (°C)
+25
+125
-55
+25
+125
-55
+25
+125
-55
+25
+125
-55
Notes
See (1)
See (1)
See (1)
Min Max Unit
-3.0 +3.0 mV
-4.0 +4.0 mV
-3.0 +3.0 mV
-4.0 +4.0 mV
-3.0 +3.0 mV
-4.0 +4.0 mV
-3.0 +3.0 mV
-4.0 +4.0 mV
-3.0 +3.0 mV
-4.5 +4.5 mV
-3.0 +3.0 mV
-4.5 +4.5 mV
-3.0 +3.0 mV
-4.5 +4.5 mV
-10 +10 nA
-20 +20 nA
-10 +10 nA
-20 +20 nA
-10 +10 nA
-20 +20 nA
Sub-
groups
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1
2, 3
1, 2
3
1, 2
3
1, 2
3
(1) Subscript (R) indicates tests which are performed with input stage current raised by connecting BAL and BAL/STB terminals to +VCC.
4
Submit Documentation Feedback
Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: LM111JAN