English
Language : 

DRV201A Datasheet, PDF (4/25 Pages) Texas Instruments – VOICE COIL MOTOR DRIVER FOR CAMERA AUTO FOCUS
DRV201A
SLVSBN6 – JUNE 2013
www.ti.com
ELECTRICAL CHARACTERISTICS (continued)
Over recommended free-air temperature range and over recommended input voltage range (typical at an ambient
temperature range of 25°C) (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
IDETCODE
Minimum VCM code for OPEN and
SHORT detection
See (2)
256
mA
fSW
Switching frequency
VDRP
Internal dropout
LVCM
VCM inductance
RVCM
VCM resistance
LENS MOVEMENT CONTROL
Selectable through CONTROL register
0.5
See (3)
30
11
4 MHz
0.4 V
150 µH
22 Ω
tset1
Lens settling time
tset2
Lens settling time
VCM resonance frequency
±10% error band
±10% error band
2/fVCM
ms
1/fVCM
ms
50
150 Hz
fVCM
VCM resonance frequency tolerance
When 1/fVCM compensation is used
-10
When 2/fVCM compensation is used
-30
10
%
30
(2) When testing VCM open or short this is the recommended minimum VCM code (in dec) to be used.
(3) This is the voltage that is needed for the feedback resistor and high side driver. It should be noted that the maximum VCM resistance is
limited by this voltage and supply voltage. E.g. 3-V supply maximum VCM resistance is: RVCM = (VBAT – VDRP)/IVCM = (3 V - 0.4
V)/102.3 mA = 25.4 Ω.
4
Submit Documentation Feedback
Product Folder Links: DRV201A
Copyright © 2013, Texas Instruments Incorporated