English
Language : 

CD74FCT573 Datasheet, PDF (4/7 Pages) Texas Instruments – BiCMOS FCT Interface Logic, Octal Transparent Latches, Three-State
CD74FCT573, CD74FCT573AT
Switching Specifications Over Operating Range FCT Series tr, tf = 2.5ns, CL = 50pF, RL (Figure 4) (Note 6)
25oC
0oC TO 70oC
PARAMETER
Propagation Delays
Data to Outputs
CD74FCT573
CD74FCT573AT
LE to Outputs
SYMBOL
VCC (V)
TYP
MIN
MAX
tPLH, tPHL
5
5
1.5
8
tPLH, tPHL
5
3.9
1.5
5.7
CD74FCT573
CD74FCT573AT
Output Enable Times
CD74FCT573
CD74FCT573AT
Output Disable Times
CD74FCT573
CD74FCT573AT
Power Dissipation Capacitance
tPLH, tPHL
5
9
2
13
tPLH, tPHL
5
4.4
2
7
tPZL, tPZH
5
tPZL, tPZH
5
7
1.5
12
6
1.5
8
tPLZ, tPHZ
5
6
1.5
7.5
tPLZ, tPHZ
5
4
1.5
5.8
CPD
-
34
-
-
(Note 7)
Minimum (Valley) VOHV During Switching of
Other Outputs (Output Under Test Not Switching)
VOHV
5
0.5
-
-
(Figure 1)
Maximum (Peak) VOLP During Switching of
Other Outputs (Output Under Test Not Switching)
VOLP
5
1
-
-
(Figure 1)
Input Capacitance
CI
-
-
Three-State Output Capacitance
CO
-
-
NOTES:
6. 5V: Min is at 5.25V for 0oC to 70oC, Max is at 4.75V for 0oC to 70oC, Typ is at 5V.
7.
CPD, measured per
PD (per package) =
flip-flop, is used to determine the
VCC ICC + Σ(VCC2 fI CPD + VO2
dynamic power consumption.
fO CL + VCC ∆ICC D) where:
VCC = supply voltage
∆ICC = flow through current x unit load
CL = output load capacitance
D = duty cycle of input high
fO = output frequency
fI = input frequency
-
10
-
15
Prerequisite for Switching
PARAMETER
Data to Latch Enable Setup Time
SYMBOL
tSU
Data to Latch Enable Hold Time
tH
Latch Enable Pulse Width
CD74FCT573
tW
CD74FCT573AT
tW
NOTE:
8. 5V: Minimum is at 4.75V for 0oC to 70oC, Typical is at 5V.
VCC (V)
5
(Note 8)
5
5
5
25oC
TYP
-
-
-
-
0oC TO 70oC
MIN
MAX
2
-
1.5
-
6
-
5
-
UNITS
ns
ns
ns
ns
ns
ns
ns
ns
pF
V
V
pF
pF
UNITS
ns
ns
ns
ns
8-4