English
Language : 

CD54ACT109_08 Datasheet, PDF (4/11 Pages) Texas Instruments – DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS WITH CLEAR AND PRESET
CD54ACT109, CD74ACT109
DUAL J-K POSITIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS327 – JANUARY 2003
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V, CL = 50 pF (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–55°C to
125°C
MIN MAX
–40°C to
85°C
MIN MAX
fmax
tPLH
CLK
CLR or PRE
Q or Q
100
2.6 10.3
3.1 12.2
114
2.7 9.4
3.2 11.1
tPHL
CLK
CLR or PRE
Q or Q
2.6 10.3
3.1 12.2
2.7 9.4
3.2 11.1
UNIT
MHz
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
Power dissipation capacitance
TYP UNIT
56
pF
4