5.13 Direct Commands from MCU to Reader
5.13.1 Command Codes
Table 5-11 lists the valid commands that the MCU can send to the reader.
www.ti.com
Command
Code
0x00
0x03
0x0F
0x10
0x11
0x16
0x17
0x18
0x19
0x1A
Table 5-11. Command Codes
Command
Idle
Software Initialization
Reset
Transmission without CRC
Transmission with CRC
Block Receiver
Enable Receiver
Test external RF (RSSI at RX input with TX on)
Test internal RF (RSSI at RX input with TX off)
Receiver Gain Adjust
Comments
Same as power on reset
The command code values from Table 5-11 are substituted in Table 5-12, Bits 0 through 4. Also, the
most-significant bit (MSB) in Table 5-12 must be set to 1.
Table 5-12. Address/Command Word Bit Distribution
Bit
Description
Bit Function
Address
Command
B7
Command control bit
0 = address
1 = command
0
1
B6
Read/Write
0 = write
1 = read
R/W
0
B5
Continuous address mode
Continuous
mode
Not used
B4
Address/Command bit 4
Adr 4
Cmd 4
B3
Address/Command bit 3
Adr 3
Cmd 3
B2
Address/Command bit 2
Adr 2
Cmd 2
B1
Address/Command bit 1
Adr 1
Cmd 1
B0
Address/Command bit 0
Adr 0
Cmd 0
The MSB determines if the word is to be used as a command or address. The last two columns of
Table 5-12 show the function of separate bits depending on whether address or command is written.
Command mode is used to enter a command resulting in reader action (for example, initialize
transmission, enable reader, or turn the reader on or off).
5.13.2 Reset (0x0F)
The reset command clears the FIFO contents and FIFO Status register (0x1C). It also clears the register
storing the collision error location (0x0E).
5.13.3 Transmission With CRC (0x11)
The transmission command must be sent first, followed by transmission length bytes, and FIFO data. The
reader starts transmitting after the first byte is loaded into the FIFO. The CRC byte is included in the
transmitted sequence.