English
Language : 

TPS54283 Datasheet, PDF (3/52 Pages) Texas Instruments – 2-A DUAL NON-SYNCHRONOUS CONVERTER WITH INTEGRATED HIGH-SIDE MOSFET
TPS54283, TPS54286
www.ti.com
SLUS749C – JULY 2007 – REVISED OCTOBER 2007
ELECTRICAL CHARACTERISTICS
–40°C ≤ TJ ≤ +125°C, VPVDD1 = VPVDD2 = 12 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
INPUT SUPPLY (PVDD)
VPVDD1
VPVDD2
IDDSDN
IDDQ
IDDSW
Input voltage range
Shutdown
Quiescent, non-switching
Quiescent, while-switching
VEN1 = VEN2 = VPVDD2
VFB = 0.9V, Outputs off
SW node unloaded; Measured as BP sink
current
VUVLO
VUVLO(hys)
tSTART (1) (2)
Minimum turn-on voltage
Hysteresis
Time from startup to softstart begin
PVDD2 only
CBP = 10 µF, EN1 and EN2 go low
simultaneously
ENABLE (EN)
VEN1
VEN2
Enable threshold
Hysteresis
IEN1
IEN2
tEN (1)
Enable pull-up current
Time from enable to soft-start begin
BP REGULATOR (BP)
VEN1 = VEN2 = 0 V
Other EN pin = GND
BP
Regulator voltage
BPLDO
Dropout voltage
IBP (1)
Regulator external load
IBPS
Regulator short circuit
OSCILLATOR
8 V < PVDD2 < 28 V
PVDD2 = 4.5 V; switching, no external load on
BP
4.5 V < PVDD2 < 28 V
fSW
Switching frequency
TPS54283
TPS54286
tDEAD (1)
Clock dead time
ERROR AMPLIFIER (EA) and VOLTAGE REFERENCE (REF)
VFB1
VFB2
Feedback input voltage
IFB1
IFB2
gM1 (1)
gM2 (1)
Feedback input bias current
Transconductance
SOFT START (SS)
0°C < TJ < +85°C
–40°C < TJ < +125°C
TSS1
TSS2
Soft start time
OVERCURRENT PROTECTION
ICL1
Current limit channel 1
ICL2
Current limit channel 2
VUV1
VUV2
THICCUP (1)
tON1(oc) (1)
tON2(oc) (1)
Low-level output threshold to declare a fault
Hiccup timeout
Minimum overcurrent pulse width
VILIM2 = VBP
VILIM2 = (floating)
VILIM2 = GND
Measured at feedback pin.
MIN TYP MAX UNIT
4.5
28
V
70
150 µA
1.8
3.0
mA
5
3.8
4.1
400
4.4
V
mV
2
ms
0.9
1.2
1.5
V
50
mV
6
12 µA
10
µs
5 5.25
400
10
20
5.6
V
mV
2
mA
30
255
310
375
kHz
510
630
750
140
ns
788
800
812
mV
786
812
3
50 nA
30
µS
1.5
2.1
2.7 ms
2.4
3.0
3.6
1.15 1.50 1.75
A
2.4
3.0
3.6
1.15 1.50 1.75
670
mV
10
ms
90
150 ns
(1) Ensured by design. Not production tested.
(2) When both outputs are started simultaneously, a 20-mA current source charges the BP capacitor. Faster times are possible with a lower
BP capacitor value. More information can be found in the Input UVLO and Startup section.
Copyright © 2007, Texas Instruments Incorporated
Submit Documentation Feedback
3
Product Folder Link(s): TPS54283 TPS54286