English
Language : 

TLC552C Datasheet, PDF (3/9 Pages) Texas Instruments – DUAL LINCMOSE TIMER
TLC552C
DUAL LINCMOS™ TIMER
SLFS046 – FEBRUARY 1984 – REVISED MAY 1988
electrical characteristics at specified free-air temperature, VDD = 1 V
PARAMETER
TEST CONDITIONS
TA†
Threshold voltage level
25°C
Full range
Threshold current
25°C
MAX
Trigger voltage level
25°C
Full range
Trigger current
25°C
MAX
Reset voltage level
25°C
Full range
Reset current
25°C
MAX
Control voltage (open-circuit) as a percentage of supply voltage
MAX
Discharge switch on-state voltage
IOL = 100 µA
25°C
Full range
Discharge switch off-state current
25°C
MAX
Low-level output voltage
IOL = 100 µA
25°C
Full range
High-level output voltage
IOH = – 10 µA
25°C
Full range
Supply current
25°C
Full range
† Full range (MIN to MAX) is 0°C to 70°C.
MIN TYP MAX
0.475 0.67 0.85
0.45
0.875
10
75
0.15 0.33 0.425
0.1
1.45
10
75
0.4 0.7
1
0.3
1
10
75
66.7%
0.02 0.15
0.2
0.1
0.5
0.03 0.2
0.25
0.6 0.98
0.6
30 200
300
UNIT
V
pA
V
pA
V
pA
V
nA
V
V
µA
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
3