English
Language : 

TL750L Datasheet, PDF (3/19 Pages) Texas Instruments – LOW-DROPOUT VOLTAGE REGULATORS
www.ti.com
Absolute Maximum Ratings(1)
over operating junction temperature range (unless otherwise noted)
TL750L, TL751L SERIES
LOW-DROPOUT VOLTAGE REGULATORS
SLVS017S – SEPTEMBER 1987 – REVISED AUGUST 2005
Continuous input voltage
Transient input voltage(2)
Continuous reverse input voltage
Transient reverse input voltage
TJ
Operating virtual junction temperature
Lead temperature
Tstg
Storage temperature range
TA = 25°C
t ≤ 100 ms
1,6 mm (1/16 in) for 10 s
MIN MAX UNIT
26 V
60 V
–15 V
–50 V
150 °C
260 °C
–65
150 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The transient input voltage rating applies to the waveform shown in Figure 1.
Package Thermal Data(1)
PACKAGE
PDIP (P)
PowerFLEX™ (KTE)
SOIC (D)
TO-226/TO-92 (LP)
TO-220 (KC)
BOARD
High K, JESD 51-7
High K, JESD 51-5
High K, JESD 51-7
High K, JESD 51-7
High K, JESD 51-5
θJC
57°C/W
3°C/W
39°C/W
55°C/W
3°C/W
θJA
85°C/W
23°C/W
97°C/W
140°C/W
19°C/W
(1) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
Recommended Operating Conditions
over recommended operating junction temperature range (unless otherwise noted)
VI
Input voltage
VIH
VIL (1)
IO
TJ
High-level ENABLE input voltage
Low-level ENABLE input voltage
Output current
Operating virtual junction temperature
TJ = 25°C
TJ = 0°C to 125°C
TL75xL05
TL75xL08
TL75xL10
TL75xL12
TL75xLxx
TL75xLxx
TL75xLxx
TL75xLxx
TL75xLxxC
MIN
6
9
11
13
2
–0.3
–0.15
0
0
MAX
26
26
26
26
15
0.8
0.8
150
125
UNIT
V
V
V
mA
°C
(1) The algebraic convention, in which the least positive (most negative) value is designated minimum, is used in this data sheet for
ENABLE voltage levels and temperature only.
3