recommended operating conditions
VCC
VIH
VIL
IIK
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
Low-level output current
Operating free-air temperature
SN74F377A
OCTAL D-TYPE FLIP-FLOP
WITH CLOCK ENABLE
SDFS018D – D2932, MARCH 1987 – REVISED OCTOBER 1993
MIN NOM MAX UNIT
4.5
5 5.5 V
2
V
0.8 V
– 18 mA
– 1 mA
20 mA
0
70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP† MAX UNIT
VOH
VCC = 4.5 V,
VCC = 4.75 V,
IOH = – 1 mA
IOH = – 1 mA
2.5 3.4
V
2.7
VOL
VCC = 4.5 V,
IOL = 20 mA
0.3 0.5 V
II
VCC = 0,
VI = 7 V
0.1 mA
IIH
VCC = 5.5 V,
VI = 2.7 V
20 µA
IIL
IOS‡
VCC = 5.5 V,
VCC = 5.5 V,
VI = 0.5 V
VO = 0
– 0.6 mA
– 60
– 150 mA
ICCH
VCC = 5.5 V,
See Note 2
55
72 mA
ICCL
VCC = 5.5 V,
See Note 3
70
90 mA
† All typical values are at VCC = 5 V, TA = 25°C.
‡ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
NOTES: 2. ICCH is measured after applying a momentary ground, then 4.5 V, to the clock input with all data inputs at 4.5 V and the enable input
at GND.
3. ICCL is measured after applying a momentary ground, then 4.5 V, to the clock input with all data and enable inputs at GND.
timing requirements
VCC = 5 V, VCC = 4.5 V to 5.5 V,
TA = 25°C TA = MIN to MAX§
MIN MAX
MIN MAX
fclock
tw
Clock frequency
Pulse duration
Data high or low
0 110
4
2
0
110
5
2
tsu
Setup time before CLK↑
CE high
CE low
2.5
2.5
4
4.5
th
Hold time after CLK↑
Data high or low
1
1
CE high or low
0
0
§ For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
UNIT
MHz
ns
ns
ns
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
2–3