English
Language : 

SN74CBTLV3383 Datasheet, PDF (3/6 Pages) Texas Instruments – LOW-VOLTAGE 10-BIT FET BUS-EXCHANGE SWITCH
SN74CBTLV3383
LOW-VOLTAGE 10-BIT FET BUS-EXCHANGE SWITCH
SCDS047D – MARCH 1998 – REVISED NOVEMBER 1999
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 4.6 V
Continuous channel current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA
Input clamp current, IIK (VI/O < 0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –50 mA
Package thermal impedance, θJA (see Note 2): DBQ package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61°C/W
DGV package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
DW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46°C/W
PW package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51.
recommended operating conditions (see Note 3)
MIN MAX UNIT
VCC
VIH
Supply voltage
High-level control input voltage
VIL
Low-level control input voltage
TA
Operating free-air temperature
VCC = 2.3 V to 2.7 V
VCC = 2.7 V to 3.6 V
VCC = 2.3 V to 2.7 V
VCC = 2.7 V to 3.6 V
2.3 3.6 V
1.7
V
2
0.7
V
0.8
–40
85 °C
NOTE 3: All unused control inputs of the device must be held at VCC or GND to ensure proper device operation. Refer to the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP‡ MAX UNIT
VIK
VCC = 3 V,
II = –18 mA
–1.2 V
II
VCC = 3.6 V,
VI = VCC or GND
±1 µA
Ioff
VCC = 0,
VI or VO= 0 to 3.6 V
10 µA
ICC
VCC = 3.6 V,
∆ICC§ Control inputs VCC = 3.6 V,
IO = 0,
One input at 3 V,
VI = VCC or GND
Other inputs at VCC or GND
10 µA
300 µA
Ci
Control inputs VI = 3 V or 0
3.5
pF
Cio(OFF)
VO = 3 V or 0,
BE = VCC
13.5
pF
VCC = 2.3 V,
VI = 0
TYP at VCC = 2.5 V
II = 64 mA
II = 24 mA
ron¶
VCC = 3 V
VI = 1.7 V,
VI = 0
II = 15 mA
II = 64 mA
II = 24 mA
5
8
5
8
27
40
Ω
5
7
5
7
VI = 2.4 V,
II = 15 mA
10
15
‡ All typical values are at VCC = 3.3 V (unless otherwise noted), TA = 25°C.
§ This is the increase in supply current for each input that is at the specified voltage level rather than VCC or GND.
¶ Measured by the voltage drop between the A and B terminals at the indicated current through the switch. On-state resistance is determined by
the lower of the voltages of the two (A or B) terminals.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265