English
Language : 

CDC351DBR Datasheet, PDF (3/13 Pages) Texas Instruments – 1-LINE TO 10-LINE CLOCK DRIVER WITH 3-STATE OUTPUTS
www.ti.com
CDC351. CDC351I
1-LINE TO 10-LINE CLOCK DRIVER WITH 3-STATE OUTPUTS
SCAS441D – FEBRUARY 1994 – REVISED OCTOBER 2003
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted) (1)
Supply voltage range, VCC
Input voltage range, VI (2)
Voltage range applied to any output in the
high state or power-off state,
VO (2)
Current into any output in the low state, IO
Input clamp current, IIK(VI < 0)
Output clamp current, IOK (VI < 0)
Package thermal impedance ΘJA (3):
DB package
DW package
Storage temperature range, Tstg
– 0.5 V to 4.6 V
– 0.5 V to 7 V
– 0.5 V to 3.6 V
64 mA
– 18 mA
– 50 mA
147°C/ W
101°C/ W
– 65°C to 150°C
(1) Stresses beyond those listed under,, absolute maximum ratings” may cause permanent damage to the device. These are stress
ratings only, and functional operation of the device at these or any other conditions beyond those indicated under,, recommended
operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The input and output negative-voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
(3) The package thermal impedance is calculated in accordance with JESD51.
RECOMMENDED OPERATING CONDITIONS (1)
VCC
VIH
VIL
VI
IOH
IOL
fclock
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
High-level output current
Low-level output current
Input clock frequency
Operating free-air temperature
Commercial
Industrial
MIN MAX UNIT
3 3.6 V
2
V
0.8 V
0 5.5 V
– 32 mA
32 mA
100 MHz
0
70 °C
– 40
85 °C
(1) Unused pins (input or I/O) must be held high or low.
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VIK
VOH
VOL
II
IO (1)
IOZ
ICC
Ci
Co
TEST CONDITIONS
VCC = 3 V,
VCC = 3 V,
VCC = 3 V,
VCC = 3.6 V,
VCC = 3.6 V,
VCC = 3.6 V,
II = –18 mA
IOH = –32 mA
IOL = 32 mA
VI = VCC or GND
VO = 2.5 V
VO = 3 V or 0
VCC = 3.6 V, IO = 0, VI = VCC or GND
VI = VCC or GND,
VO = VCC or GND,
VCC = 3.3 V,
VCC = 3.3 V,
Outputs high
Outputs low
Outputs disabled
f = 10 MHz
f = 10 MHz
MIN TYP MAX UNIT
–1.2 V
2
V
0.5 V
±1 µA
–15
–150 mA
±10 µA
0.3
25 mA
0.3
4
pF
6
pF
(1) Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
3