English
Language : 

AMC1200_1108 Datasheet, PDF (3/23 Pages) Texas Instruments – Fully-Differential Isolation Amplifier
AMC1200
www.ti.com
SBAS542A – APRIL 2011 – REVISED AUGUST 2011
IEC 60747-5-2 INSULATION CHARACTERISTICS
Over operating free-air temperature range (unless otherwise noted).
PARAMETER
TEST CONDITIONS
VIORM
Maximum working insulation voltage
Qualification test: after Input/Output Safety Test
Subgroup 2/3 VPR = VIORM x 1.2, t = 10 s, partial
discharge < 5 pC
VPR
Input to output test voltage
Qualification test: method a, after environmental tests
subgroup 1, VPR = VIORM x 1.6, t = 10 s, partial discharge
< 5 pC
100% production test: method b1, VPR = VIORM x 1.875,
t = 1 s, partial discharge < 5 pC
VIOTM
VISO
RS
PD
Transient overvoltage
Insulation voltage per UL
Insulation resistance
Pollution degree
Qualification test: t = 60 s
Qualification test: VTEST = VISO , t = 60 s
100% production test: VTEST = 1.2 x VISO , t = 1 s
VIO = 500 V at TS
VALUE
1200
1140
1920
2250
4000
4000
4800
> 109
2
UNIT
VPEAK
VPEAK
VPEAK
VPEAK
VPEAK
VPEAK
VPEAK
Ω
°
IEC SAFETY LIMITING VALUES
Safety limiting intends to prevent potential damage to the isolation barrier upon failure of input or output (I/O) circuitry. A
failure of the I/O circuitry can allow low resistance to ground or the supply and, without current limiting, dissipate sufficient
power to overheat the die and damage the isolation barrier, potentially leading to secondary system failures.
The safety-limiting constraint is the operating virtual junction temperature range specified in the Absolute Maximum Ratings
table. The power dissipation and junction-to-air thermal impedance of the device installed in the application hardware
determine the junction temperature. The assumed junction-to-air thermal resistance in the Thermal Information table is that of
a device installed in the JESD51-3, Low Effective Thermal Conductivity Test Board for Leaded Surface Mount Packages and
is conservative. The power is the recommended maximum input voltage times the current. The junction temperature is then
the ambient temperature plus the power times the junction-to-air thermal resistance.
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
IS Safety input, output, or supply current
TC Maximum case temperature
θJA = 246°C/W, VIN = 5.5 V, TJ = +150°C, TA = +25°C
10 mA
+150 °C
IEC 61000-4-5 RATINGS
PARAMETER
VIOSM Surge immunity
TEST CONDITIONS
1.2-μs/50-μs voltage surge and 8-μs/20-μs current surge
VALUE
±6000
UNIT
V
IEC 60664-1 RATINGS
PARAMETER
Basic isolation group
Installation classification
TEST CONDITIONS
Material group
Rated mains voltage ≤ 150 VRMS
Rated mains voltage ≤ 300 VRMS
Rated mains voltage ≤ 400 VRMS
Rated mains voltage < 600 VRMS
SPECIFICATION
II
I-IV
I-IV
I-III
I-III
Copyright © 2011, Texas Instruments Incorporated