MSP430F1122 Datasheet, PDF (28/48 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER | |||
|
◁ |
MSP430x11x2, MSP430x12x2
MIXED SIGNAL MICROCONTROLLER
SLAS361C â JANUARY 2002 â REVISED DECEMBER 2003
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
10-bit ADC, temperature sensor and built-in VMID
PARAMETER
TEST CONDITIONS
MIN NOM
MAX UNIT
ISENSOR
Operating supply current into
VCC terminal (see Note 1)
REFON = 0, INCH = 0Ah,
ADC10ON=NA, TA = 25_C
2.2 V
3V
40
120
µA
60
160
VSENSORâ
ADC10ON = 1, INCH = 0Ah,
TA = 0°C
2.2 V
3V
986 986±5%
mV
986 986±5%
TCSENSORâ
ADC10ON = 1, INCH = 0Ah
2.2 V
3V
3.55 3.55±3%
mV/°C
3.55 3.55±3%
tSENSOR(sample)â
Sample time required if channel
10 is selected (see Note 2)
ADC10ON = 1, INCH = 0Ah,
2.2 V
Error of conversion result ⤠1 LSB 3 V
30
30
µs
IVMID
Current into divider at channel 11
(see Note 3)
ADC10ON = 1, INCH = 0Bh,
2.2 V
3V
NA
µA
NA
VMID
VCC divider at channel 11
ADC10ON = 1, INCH = 0Bh,
VMID is ~0.5 x VCC
2.2 V
3V
1.1 1.1±0.04
V
1.5 1.50±0.04
tVMID(sample)
Sample time required if channel ADC10ON = 1, INCH = 0Bh,
2.2 V 1400
11 is selected (see Note 4)
Error of conversion result ⤠1 LSB 3 V 1220
ns
â Not production tested, limits characterized
NOTES: 1. The sensor current ISENSOR is consumed if (ADC10ON = 1 and REFON = 1), or (ADC10ON=1 and INCH=0Ah and sample signal
is high). Therefore it includes the constant current through the sensor and the reference.
2. The typical equivalent impedance of the sensor is 51 kâ¦. The sample time required includes the sensor-on time tSENSOR(on).
3. No additional current is needed. The VMID is used during sampling.
4. The on-time tVMID(on) is included in the sampling time tVMID(sample); no additional on time is needed.
28
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |