TPIC83000-Q1 Datasheet, PDF (26/44 Pages) Texas Instruments – PRESSURE SENSOR SIGNAL CONDITIONING INTERFACE
TPIC83000-Q1
SLDS171 – NOVEMBER 2009
www.ti.com
Table 17. Profile of Calibration Read Data Frames (Field Mode Addressing) (continued)
FIELD NAME
(BANK ADDRESS)
History of OP timer
FIELD
MODE
ADDRESS
10000
LENGTH
(1:0)
History OP gain
10001
(2:0)
History of Input
offset
History of Input
offset first order
temperature
coefficient
History of Input
offset 2nd order
temperature
coefficient
History of Gain
adjust
History of Gain first
order temperature
coefficient
10010
10011
10100
10101
10110
(17:0)
(6:0)
(6:0)
(8:0)
(5:0)
FRAME
NO.
1
1
1
2
3
B7 (MSB)
B6
B5
B4
B3
B2
B1
B0 (LSB)
DATA
MTR
DELAY(1)
MTR
DELAY(0)
NU
NU
NU
NU
NU
NU
MTRHS
GAIN(2)
MTRHS
GAIN(1)
MTRHS
GAIN(0)
NU
NU
NU
NU
NU
MTR
VOS(17)
MTR
VOS(16)
MTR
VOS(15)
MTR
VOS(14)
MTR
VOS(13)
MTR
VOS(12)
MTR
VOS(11)
MTR
VOS(10)
MTR VOS(9) MTR VOS(8) MTR VOS(7) MTR VOS(6) MTR VOS(5) MTR VOS(4) MTR VOS(3) MTR VOS(2)
MTR VOS(1) MTR VOS(0)
NU
NU
NU
NU
NU
NU
1
MTRTC
VOS1(6)
MTRTC
VOS1(5)
MTRTC
VOS1(4)
MTRTC
VOS1(3)
MTRTC
VOS1(2)
MTRTC
VOS1(1)
MTRTC
VOS1(0)
NU
1
MTRTC
VOS2(6)
MTRTC
VOS2(5)
MTRTC
VOS2(4)
MTRTC
VOS2(3)
MTRTC
VOS2(2)
MTRTC
VOS2(1)
MTRTC
VOS2(0)
NU
1
MTRGAIN(8) MTRGAIN(7) MTRGAIN(6) MTRGAIN(5) MTRGAIN(4) MTRGAIN(3) MTRGAIN(2) MTRGAIN(1)
2
MTRGAIN(0)
NU
NU
NU
NU
NU
NU
NU
1
MTRTC
GAIN1(5)
MTRTC
GAIN1(4)
MTRTC
GAIN1(3)
MTRTC
GAIN1(2)
MTRTC
GAIN1(1)
MTRTC
GAIN1(0)
NU
NU
Table 18. Profile of Calibration Read Data Frames (Bank Mode Addressing)
FIELD NAME
(BANK ADDRESS)
FIELD
MODE
ADDRESS
LENGTH
Sensor ID 0
00000
(43:0)
Position ID (0)
OP threshold(1)
OP timer(1)
OP gain(1)
Baud rate(2)
Input coarse offset
(3)
Input fine offset(3)
Input offset first
order temperature
coefficient(3)
Input offset second
order temperature
coefficient(3)
Gain adjust(3)
Gain first order
temperature
coefficient(3)
Temperature sensor
OUT 1 (4)
Temperature sensor
OUT 2 (4)
Temperature sensor
OUT 3 (4)
00001
00010
00011
00100
(1:0)
(3:0)
(1:0)
(2:0)
(3:0)
(16:8)
(7:0)
(6:0)
(6:0)
(8:0)
(5:0)
(11:0)
(11:0)
(11:0)
FRAME
NO.
1
2
3
4
5
6
7
1
2
3
1
1
2
3
B7 (MSB)
B6
B5
SENID(43) SENID(42)
SENID(35) SENID(34)
SENID(27) SENID(26)
SENID(19) SENID(18)
SENID(11) SENID(10)
SENID(3)
SENID(2)
PSNID(1)
PSNID(0)
TRHS(3)
TRHS(2)
TRDELAY(1) TRDELAY(0)
TRHS
GAIN(2)
TRHS
GAIN(1)
CONF
BPS(3)
CONF
BPS(2)
TRV
OSC(16)
TRV
OSC(15)
TRV OSC(8)
NU
SENID(41)
SENID(33)
SENID(25)
SENID(17)
SENID(9)
SENID(1)
NU
TRHS(1)
NU
TRHS
GAIN(0)
CONF
BPS(1)
TRV
OSC(14)
NU
TRVOSF(7) TRVOSF(6) TRVOSF(5)
B4
B3
DATA
SENID(40)
SENID(32)
SENID(24)
SENID(16)
SENID(8)
SENID(0)
NU
TRHS(0)
NU
SENID(39)
SENID(31)
SENID(23)
SENID(15)
SENID(7)
NU
NU
NU
NU
NU
NU
CONF
BPS(0)
TRV
OSC(13)
NU
NU
TRV
OSC(12)
NU
TRVOSF(4) TRVOSF(3)
B2
SENID(38)
SENID(30)
SENID(22)
SENID(14)
SENID(6)
NU
NU
NU
NU
NU
NU
TRV
OSC(11)
NU
TRVOSF(2)
B1
B0 (LSB)
SENID(37)
SENID(29)
SENID(21)
SENID(13)
SENID(5)
NU
NU
NU
NU
SENID(36)
SENID(28)
SENID(20)
SENID(12)
SENID(4)
NU
NU
NU
NU
NU
NU
TRV
OSC(10)
NU
NU
TRV OSC(9)
TRVOSF(1)
TRTC
VOS1(1)
NU
TRVOSF(0)
4
TRTC
VOS1(6)
TRTC
VOS1(5)
TRTC
VOS1(4)
TRTC
VOS1(3)
TRTC
VOS1(2)
TRTC
VOS1(1)
TRTC
VOS2(0)
NU
5
TRTC
VOS2(6)
TRTC
VOS2(5)
TRTC
VOS2(4)
TRTC
VOS2(3)
TRTC
VOS2(2)
TRTC
VOS2(1)
TRGAIN(2)
NU
6
TRGAIN(8) TRGAIN(7) TRGAIN(6) TRGAIN(5) TRGAIN(4) TRGAIN(3)
NU
TRGAIN(1)
7
TRGAIN(0)
NU
NU
NU
NU
NU
NU
NU
8
TRTC
GAIN1(5)
TRTC
GAIN1(4)
TRTC
GAIN1(3)
TRTC
GAIN1(2)
TRTC
GAIN1(1)
TRTC
GAIN1(0)
TEMP0(5)
NU
1
TEMP0(11) TEMP0(10) TEMP0(9) TEMP0(8) TEMP0(7) TEMP0(6)
NU
TEMP0(4)
2
TEMP0(3) TEMP0(2) TEMP0(1) TEMP0(0)
NU
NU
TEMP1(5)
NU
3
TEMP1(11) TEMP1(10) TEMP1(9) TEMP1(8) TEMP1(7) TEMP1(6)
NU
TEMP1(4)
4
TEMP1(3) TEMP1(2) TEMP1(1) TEMP1(0)
NU
NU
TEMP2(5)
NU
5
TEMP2(11) TEMP2(10) TEMP2(9) TEMP2(8) TEMP2(7) TEMP2(6)
NU
TEMP2(4)
6
TEMP2(3) TEMP2(2) TEMP2(1) TEMP2(0)
NU
NU
NU
NU
26
Submit Documentation Feedback
Product Folder Link(s): TPIC83000-Q1
Copyright © 2009, Texas Instruments Incorporated