English
Language : 

MSP430X20X1 Datasheet, PDF (24/80 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430x20x1, MSP430x20x2, MSP430x20x3
MIXED SIGNAL MICROCONTROLLER
SLAS491A − AUGUST 2005 − REVISED OCTOBER 2005
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
outputs − Ports P1 and P2
PARAMETER
TEST CONDITIONS
VCC
MIN
TYP MAX UNIT
VOH
VOL
NOTES:
I(OHmax) = −1.5 mA (see Notes 1)
2.2 V
VCC−0.25
VCC
High-level output
voltage
I(OHmax) = −6 mA (see Notes 2)
I(OHmax) = −1.5 mA (see Notes 1)
2.2 V
3V
VCC−0.6
VCC−0.25
VCC
V
VCC
I(OHmax) = −6 mA (see Notes 2)
3V
VCC−0.6
VCC
I(OLmax) = 1.5 mA (see Notes 1)
2.2 V
VSS
VSS+0.25
Low-level output
voltage
I(OLmax) = 6 mA (see Notes 2)
I(OLmax) = 1.5 mA (see Notes 1)
2.2 V
3V
VSS
VSS
VSS+0.6
V
VSS+0.25
I(OLmax) = 6 mA (see Notes 2)
3V
VSS
VSS+0.6
1. The maximum total current, IOHmax and IOLmax, for all outputs combined, should not exceed ±12 mA to hold the maximum
voltage drop specified.
2. The maximum total current, IOHmax and IOLmax, for all outputs combined, should not exceed ±48 mA to hold the maximum
voltage drop specified.
output frequency − Ports P1 and P2
PARAMETER
TEST CONDITIONS
VCC
MIN TYP
MAX UNIT
fPx.y
Port output frequency
(with load)
P1.4/SMCLK, CL = 20 pF, RL = 1 kOhm
(see Note 1 and 2)
2.2 V
3V
10 MHz
12 MHz
fPort_CLK
Clock output frequency
P2.0/ACLK, P1.4/SMCLK, CL = 20 pF
(see Note 2)
2.2 V
3V
12 MHz
16 MHz
NOTES: 1. A resistive divider with 2 times 0.5 kW between VCC and VSS is used as load. The output is connected to the center tap of the divider.
2. The output voltage reaches at least 10% and 90% VCC at the specified toggle frequency.
24