English
Language : 

MSP430FG42X0 Datasheet, PDF (24/65 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430FG42x0
MIXED SIGNAL MICROCONTROLLER
SLAS556A − JULY 2007 − REVISED AUGUST 2007
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
POR/brownout reset (BOR) (see Note 1)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
td(BOR)
VCC(start)
V(B_IT−)
Vhys(B_IT−)
t(reset)
2000 μs
dVCC/dt ≤ 3 V/s (see Figure 6)
0.7 × V(B_IT−)
V
Brownout
(see Note 2)
dVCC/dt ≤ 3 V/s (see Figure 6 through Figure 8)
dVCC/dt ≤ 3 V/s (see Figure 6)
1.71
V
70
130
180 mV
Pulse length needed at RST/NMI pin to accepted reset internally,
VCC = 2.2 V/3 V
2
μs
NOTES:
1. The current consumption of the brownout module is already included in the ICC current consumption data. The voltage level
V(B_IT−) + Vhys(B_IT−) is ≤ 1.8V.
2. During power up, the CPU begins code execution following a period of td(BOR) after VCC = V(B_IT−) + Vhys(B_IT−). The default
FLL+ settings must not be changed until VCC ≥ VCC(min), where VCC(min) is the minimum supply voltage for the desired
operating frequency. See the MSP430x4xx Family User’s Guide (SLAU056) for more information on the brownout.
typical characteristics
VCC
Vhys(B_IT−)
V(B_IT−)
VCC(start)
1
0
t d(BOR)
Figure 6. POR/Brownout Reset (BOR) vs Supply Voltage
24
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265