MSP430x11x2, MSP430x12x2
MIXED SIGNAL MICROCONTROLLER
SLAS361C − JANUARY 2002 − REVISED DECEMBER 2003
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
ÎÎÎÎÎÎ Max
f(DCOx7)
ÎÎÎÎÎÎ Min
Max
ÎÎÎÎÎÎ f(DCOx0)
ÎÎÎÎÎÎ Min
2.2 V
3V
VCC
0 1 2 34 56 7
DCO Steps
Figure 9. DCO Characteristics
principle characteristics of the DCO
D Individual devices have a minimum and maximum operation frequency. The specified parameters for
fDCOx0 to fDCOx7 are valid for all devices.
D The DCO control bits DCO0, DCO1 and DCO2 have a step size as defined in parameter SDCO.
D The modulation control bits MOD0 to MOD4 select how often fDCO+1 is used within the period of 32 DCOCLK
cycles. fDCO is used for the remaining cycles. The frequency is an average = fDCO × (2MOD/32).
D All ranges selected by Rsel(n) overlap with Rsel(n+1): Rsel0 overlaps with Rsel1, ... Rsel6 overlaps with Rsel7.
wake-up from lower power modes (LPMx)
PARAMETER
TEST CONDITIONS
t(LPM0)
VCC = 2.2 V/3 V
t(LPM2)
VCC = 2.2 V/3 V
f(MCLK) = 1 MHz,
t(LPM3)
Delay time (see Note 1)
f(MCLK) = 2 MHz,
f(MCLK) = 3 MHz,
f(MCLK) = 1 MHz,
t(LPM4)
f(MCLK) = 2 MHz,
f(MCLK) = 3 MHz,
NOTES: 1. Parameter applicable only if DCOCLK is used for MCLK.
VCC = 2.2 V/3 V
VCC = 2.2 V/3 V
VCC = 2.2 V/3 V
VCC = 2.2 V/3 V
VCC = 2.2 V/3 V
VCC = 2.2 V/3 V
MIN TYP MAX UNIT
100
ns
100
6
6 µs
6
6
6 µs
6
24
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265