absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 1.2 V to 7 V
Input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30 mA to 5 mA
Voltage range applied to any output in the disabled or power-off state . . . . . . . . . . . . . . . . . . . – 0.5 V to 5.5 V
Voltage range applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC
Current into any output in the low state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 mA
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed.
recommended operating conditions
VCC
VIH
VIL
IIK
IOH
IOL
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input clamp current
High-level output current
Low-level output current
Operating free-air temperature
MIN NOM MAX UNIT
4.5
5 5.5 V
2
V
0.8 V
– 18 mA
– 15 mA
64 mA
0
70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP‡ MAX UNIT
VIK
VCC = 4.5 V,
II = – 18 mA
– 1.2 V
VOH
VCC = 4.5 V
IOH = – 3 mA
IOH = – 15 mA
2.4 3.3
2 3.1
V
VCC = 4.75 V,
IOH = – 3 mA
2.7
VOL
VCC = 4.5 V,
IOL = 64 mA
0.4 0.55 V
II
VCC = 0,
VI = 7 V
0.1 mA
IIH
VCC = 5.5 V,
VI = 2.7 V
20 µA
IIL
VCC = 5.5 V,
VI = 0.5 V
– 20 µA
IOZH
VCC = 5.5 V,
VO = 2.7 V
50 µA
IOZL
IOS§
VCC = 5.5 V,
VCC = 5.5 V,
VO = 0.5 V
VO = 0
– 100
– 50 µA
– 225 mA
ICCH
VCC = 5.5 V,
Outputs open
20
30 mA
ICCL
VCC = 5.5 V,
Outputs open
32
48 mA
ICCZ
VCC = 5.5 V,
Outputs open
26
‡ All typical values are at VCC = 5 V, TA = 25°C.
§ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second.
39 mA
2–2