English
Language : 

OPA340-EP_15 Datasheet, PDF (2/19 Pages) Texas Instruments – SINGLE-SUPPLY RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
OPA340-EP
SBOS433A – AUGUST 2008 – REVISED APRIL 2011
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
TA
–55°C to 125°C
ORDERING INFORMATION(1)
PACKAGE (2)
SOIC – D (8 pin)
Reel of 2500
ORDERABLE PART NUMBER
OPA340MDREP (3)
SOT23-5 – DBV
Reel of 250
OPA340MDBVTEP
TOP-SIDE MARKING
PREVIEW
CVS
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
web site at www.ti.com.
(2) Package drawings, thermal data, and symbolization are available at www.ti.com/packaging.
(3) Product preview. Contact your TI sales representative for availability.
ABSOLUTE MAXIMUM RATINGS(1)
VS
Supply voltage
VI
Signal input voltage(2)
VO
Signal input current(2)
Output short-circuit(3)
5.5 V
(V–) – 0.5 V to (V+) + 0.5 V
10 mA
Continuous
TA
Operating free-air temperature range
Tstg Storage temperature range
TJ
Operating virtual-junction temperature
–55°C to 125°C
–55°C to 125°C
150°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Input terminals are diode-clamped to the power-supply rails. Input signals that can swing more than 0.5 V beyond the supply rails should
be current limited to 10 mA or less.
(3) Short-circuit to ground, one amplifier per package.
2
Copyright © 2008–2011, Texas Instruments Incorporated