English
Language : 

OPA209_10 Datasheet, PDF (2/25 Pages) Texas Instruments – OPERATIONAL AMPLIFIER
OPA209
OPA2209
OPA4209
SBOS426B – NOVEMBER 2008 – REVISED AUGUST 2010
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
PRODUCT
OPA209
OPA2209
OPA4209
ORDERING INFORMATION(1)
PACKAGE-LEAD
PACKAGE DESIGNATOR
SOT23-5
DBV
MSOP-8
DGK
SO-8
D
MSOP-8
DGK
SO-8
D
TSSOP-14
PW
PACKAGE MARKING
OOBQ
OOAQ
OPA209A
OOJI
O2209
OPA4209
(1) For the most current package and ordering information see the Package Option Addendum at the end of this document, or see the TI
web site at www.ti.com.
ABSOLUTE MAXIMUM RATINGS(1)
Supply Voltage
Signal Input Terminal, Voltage(2)
VS = (V+) – (V–)
Signal Input Terminal, Current (except power-supply pins)(2)
Output Short-Circuit(3)
Operating Temperature
TA
Storage Temperature
TA
Junction Temperature
TJ
ESD Ratings:
Human Body Model (HBM)
Charged Device Model (CDM)
OPA209, OPA2209, OPA4209
40
(V–) – 0.5 to (V+) + 0.5
10
Continuous
–55 to +150
–65 to +150
+200
3000
1000
UNIT
V
V
mA
°C
°C
°C
V
V
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may
degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those specified is not implied.
(2) For input voltages beyond the power-supply rails, voltage or current must be limited.
(3) Short-circuit to ground, one amplifier per package.