English
Language : 

CD54AC112 Datasheet, PDF (2/10 Pages) Intersil Corporation – Dual “J-K” Flip-Flop with Set and Reset
CD54AC112, CD74AC112
DUAL J-K NEGATIVE-EDGE-TRIGGERED FLIP-FLOPS
WITH CLEAR AND PRESET
SCHS325 – JANUARY 2003
FUNCTION TABLE
(each flip-flop)
INPUTS
OUTPUTS
PRE CLR CLK J
K
Q
Q
L
H
X
X
X
H
L
H
L
X
X
X
L
H
L
L
X
X
X
H†
H†
H
H
↓
L
L
Q0 Q0
H
H
↓
H
L
H
L
H
H
↓
L
H
L
H
H
H
↓
H
H
Toggle
H
H
H
X
X
Q0 Q0
† Output states are unpredictable if PRE and CLR go high
simultaneously after both being low at the same time.
logic diagram (positive logic)
Q
PRE
Q
CLR
K
J
CLK
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6 V
Input clamp current, IIK (VI < 0 V or VI > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
Output clamp current, IOK (VO < 0 V or VO > VCC) (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous output current, IO (VO > 0 V or VO < VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Package thermal impedance, θJA (see Note 2): E package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67°C/W
M package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
2
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265