English
Language : 

CD54-74FCT240 Datasheet, PDF (2/3 Pages) Texas Instruments – FCT Interface Logic Octal Buffers/Line Drivers, Three-State
CD54/74FCT540, CD54/74FCT540AT, CD54/74FCT241, CD54/74FCT244, CD54/74FCT244AT
Switching Specifications FCT Series tr, tf = 2.5ns, CL = 50pF, RL - See Figure 2
PARAMETER
SYMBOL
VCC
(V)
+25o
C
TYP
0oC to
+70oC
MIN MAX
-55oC to
+125oC
MIN MAX
+25o
C
TYP
0oC to
+70oC
MIN MAX
-55oC to
+125oC
MIN MAX UNITS
Propagation Delays
Data to Outputs FCT240/AT tPLH,
5†
5
1.5 8 1.5
9
4.4 1.5 5.6 1.5 6.7 ns
tPHL
FCT241
tPLH ,
5
4 1.5 6.5 1.5 7
-
-
-
-
-
ns
tPHL
FCT244/AT
tPLH ,
tPHL
5 4.5 1.5 6.5 1.5 7 3.8 1.5 5.3 1.5 6.2 µs
Output Enable
FCT240/AT tPZL,
5
7 1.5 10 1.5 10.5 4.7 1.5 6.2 1.5 7.7 µs
Times
tPZH
FCT241
tPZL ,
5 5.5 1.5 8 1.5 8.5 -
-
-
-
-
ns
tPZH
FCT244/AT tPZL,
5
6 1.5 8 1.5 8.5 4.8 1.5 6.5 1.5 7.8 ns
tPZH
Output Disable FCT240/AT tPLZ,
5
6 1.5 9.5 1.5 10 4 1.5 5.6 1.5 6.5 µs
Times
tPHZ
FCT241
tPLZ ,
5 4.5 1.5 7 1.5 7.5 -
-
-
-
-
ns
tPHZ
FCT244/AT tPLZ,
5
5 1.5 7 1.5 7.5 4.5 1.5 5.8 1.5 6.8 µs
tPHZ
Power Dissipation FCT240/AT CPD§
-
Capacitance
FCT241
CPD §
-
38 Typical
33 Typical
38 Typical
pF
-
pF
FCT244/AT CPD§
35 Typical
35 Typical
pF
Min. (Valley) VOHV During Switch- VOHV
5
0.5 Typical at +25oC
V
ing of Other Outputs (Output Under See
Test Not Switching)
Figure 1
Max. (Peak) VOLP During Switch- VOLP
5
1 Typical at +25oC
V
ing of Other Outputs (Output Under See
Test Not Switching)
Figure 1
Input Capacitance
CI
-
-
- 10 - 10 -
- 10 - 10 pF
3-State Output Capacitance
CO
-
-
- 15 - 15 -
- 15 - 15 pF
† 5V: min. is at 5.5V, max. is at 4.5V.
5V: min. is at 5.25V for 0oC to +70oC, max. is at 4.75V for 0oC to +70oC, typ. is at 5V
§ CPD, measured per function, is used to determine the dynamic power consumption. PD (per package) = VCC ICC + ∑ (VCC2 fi CPD + VO2
fo CL + VCC ∆ICC D) where:
VCC = supply voltage
∆ICC = flow through current x unit load
CL = output load capacitance
D = duty cycle of input high
fo = output frequency
fi = input frequency
2