MSP430F42x0
MIXED SIGNAL MICROCONTROLLER
SLAS455D − MARCH 2005 − REVISED APRIL 2007
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
SCHMITT-trigger inputs − Ports P1, P2, P5, and P6; RST/NMI; JTAG: TCK, TMS, TDI/TCLK, TDO/TDI
PARAMETER
TEST CONDITIONS MIN TYP MAX UNIT
VIT+
Positive-going input threshold voltage
VIT−
Negative-going input threshold voltage
Vhys
Input voltage hysteresis (VIT+ − VIT−)
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
VCC = 2.2 V
VCC = 3 V
1.1
1.55
V
1.5
1.98
0.4
0.9
V
0.9
1.3
0.3
1.1
V
0.5
1
inputs Px.x, TAx
PARAMETER
t(int)
External interrupt timing
TEST CONDITIONS
Port P1, P2: P1.x to P2.x, external trigger signal
for the interrupt flag, (see Note 1)
VCC
2.2 V
3V
MIN TYP MAX UNIT
62
ns
50
t(cap)
Timer_A capture timing
TA0, TA1, TA2
2.2 V
62
ns
3V
50
f(TAext)
Timer_A clock frequency
externally applied to pin
TACLK, INCLK: t(H) = t(L)
2.2 V
3V
8
MHz
10
f(TAint) Timer_A, clock frequency
SMCLK or ACLK signal selected
2.2 V
3V
8
MHz
10
NOTES: 1. The external signal sets the interrupt flag every time the minimum t(int) parameters are met. It may be set even with trigger signals
shorter than t(int).
leakage current − Ports P1, P2, P5, and P6 (see Note 1)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
Ilkg(Px.y)
Leakage
current
Port Px V(Px.y) (see Note 2)
VCC = 2.2 V/3 V
±50 nA
NOTES: 1. The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
2. The port pin must be selected as input.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265