BQ2085-V1P3 Datasheet, PDF (19/57 Pages) Texas Instruments – SBS-COMPLIANT GAS GAUGE IC FOR USE WITH THE bq29311 | |||
|
◁ |
www.ti.com
SAFE
VCC
FUSE
Cell 4
1 Mâ¦
0.1 µF
BSS84
100 kâ¦
1 Mâ¦
2N7002
bq2085-V1P3
SLUS598 â FEBRUARY 2004
BAT+
Figure 5. Example SAFE Circuit Implementation
Low-Power Modes
The bq2085âV1P3 enters sleep mode when the charge and discharge current is less than the threshold
programmed in Sleep Current Threshold DF 0xe5, the SMBus lines are low for at least 2 s, and bit 4 of Misc.
Configuration DF 0x2a is set to zero. The bq2085âV1P3 wakes up periodically to monitor voltage and
temperature and to apply self-discharge adjustment. The sleep period is set in Sleep Timer DF 0xe7. The
bq2085âV1P3 wakes up at a period set by Sleep Current Time DF 0xe6 to measure current. The bq2085âV1P3
comes out of sleep when the SMBus lines go high or if the current is greater than Sleep Current Threshold. A
rising edge on SMBC or SMBD restores the bq2085âV1P3 to the full operating mode.
Reset Conditions
On power-up the entire IC is reset and data is loaded from Data Flash to configure the SBS Data and the system.
On a partial reset (loss of VCC but RBI holds RAM valid) then a limited number of locations are taken.
These actions are the following:
D The AFE registers are rewritten.
D PackStatus() VDQ flag is cleared (the proposed change is not to clear VDQ).
D PackStatus() EDV2 flag is cleared.
D BatteryStatus() DISCHARGING flag is cleared.
D The charger and alarm broadcast period is set to 10 seconds between broadcasts.
COMMUNICATION
The bq2085âV1P3 includes an SMBus communication port. The SMBus interface is a 2-wire bidirectional
protocol using the SMBC (clock) and SMBD (data) pins. The communication lines are isolated from VCC and
may be pulled-up higher than VCC. Also, the bq2085âV1P3 does not pull these lines low if VCC to the part is
zero.
The communication ports allow a host controller, an SMBus compatible device, or other processor to access
the memory registers of the bq2085âV1P3. In this way a system can efficiently monitor and manage the battery.
SMBus
The SMBus interface is a command-based protocol. A processor acting as the bus master initiates
communication to the bq2085âV1P3 by generating a start condition. A start condition consists of a high-to-low
transition of the SMBD line while the SMBC is high. The processor then sends the bq2085âV1P3 device
address of 0001011 (bits 7-1) plus a R/W bit (bit 0) followed by an SMBus command code. The R/W bit (LSB)
and the command code instruct the bq2085âV1P3 to either store the forthcoming data to a register specified
19
|
▷ |