English
Language : 

MSP430F42X_11 Datasheet, PDF (17/45 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430F42x
MIXED SIGNAL MICROCONTROLLER
SLAS421A − APRIL 2004 − REVISED JUNE 2007
absolute maximum ratings†
Voltage applied at VCC to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to + 4.1 V
Voltage applied to any pin (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.3 V to VCC + 0.3 V
Diode current at any device terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±2 mA
Storage temperature (unprogrammed device) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −55°C to 150°C
Storage temperature (programmed device) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages referenced to VSS. The JTAG fuse-blow voltage, VFB, is allowed to exceed the absolute maximum rating. The voltage is
applied to the TDI/TCLK pin when blowing the JTAG fuse.
recommended operating conditions
PARAMETER
MIN NOM
MAX UNITS
Supply voltage during program execution; SD16 disabled.
VCC (AVCC = DVCC = VCC) (see Note 1)
MSP430F42x
1.8
3.6 V
Supply voltage during program execution; SD16 disabled, SVS enabled, and
PORON = 1. VCC (AVCC = DVCC = VCC) (see Note 1 and Note 2)
MSP430F42x
2.0
3.6 V
Supply voltage during program execution; SD16 enabled or
during programming of flash memory. VCC (AVCC = DVCC = VCC)
MSP430F42x
2.7
3.6 V
Supply voltage, VSS (AVSS = DVSS = VSS)
Operating free-air temperature range, TA
LF selected, XTS_FLL=0
MSP430F42x
Watch crystal
0
−40
32768
0V
85 °C
Hz
LFXT1 crystal frequency, f(LFXT1) (see Note 3) XT1 selected, XTS_FLL=1
XT1 selected, XTS_FLL=1
Ceramic resonator
Crystal
450
1000
8000 kHz
8000 kHz
Processor frequency (signal MCLK), f(System)
VCC = 1.8 V
DC
4.15
MHz
VCC = 3.6 V
DC
8
NOTES: 1. It is recommended to power AVCC and DVCC from the same source. A maximum difference of 0.3 V between AVCC and DVCC can
be tolerated during power up and operation.
2. The minimum operating supply voltage is defined according to the trip point where POR is going active by decreasing supply voltage.
POR is going inactive when the supply voltage is raised above minimum supply voltage plus the hysteresis of the SVS circuitry.
3. The LFXT1 oscillator in LF-mode requires a watch crystal.
f (MHz)
8 MHz
6 MHz
4.15 MHz
Supply Voltage Range with SD16
Enabled or During Programming
of the Flash Memory
ÎÎÎÎÎÎ Supply Voltage Range
ÎÎÎÎÎÎ During Program
ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ Execution
1.8 V
2.7 V 3 V
3.6 V
VCC − Supply Voltage − V
Figure 1. Frequency vs Supply Voltage
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
17