English
Language : 

TLC225X_08 Datasheet, PDF (16/74 Pages) Texas Instruments – Advanced LinCMOS RAIL-TO-RAIL VERY LOW-POWER OPERATIONAL AMPLIFIERS
TLC225x, TLC225xA
Advanced LinCMOS RAIL-TO-RAIL
VERY LOW-POWER OPERATIONAL AMPLIFIERS
SLOS176D – FEBRUARY 1997 – REVISED MARCH 2001
electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC2252I
TLC2252AI
TA†
UNIT
MIN TYP MAX MIN TYP MAX
VIO Input offset voltage
25°C
Full range
200 1500
1750
200 850
µV
1000
αVIO
Temperature coefficient of
input offset voltage
25°C
to 85°C
0.5
0.5
µV/°C
Input offset voltage long-
term drift (see Note 4)
VIC = 0,
VO = 0,
RS = 50 Ω
IIO
Input offset current
25°C
25°C
Full range
0.003
0.5
60
1000
0.003
µV/mo
0.5
60
pA
1000
IIB
Input bias current
25°C
Full range
1
60
1000
1
60
pA
1000
– 5 – 5.3
– 5 – 5.3
25°C
to
to
to
to
VICR
Common-mode input
voltage range
RS = 50 Ω, |VIO | ≤ 5 mV
4 4.2
4 4.2
V
–5
–5
Full range
to
to
3.5
3.5
VOM +
Maximum positive peak
output voltage
IO = – 20 µA
IO = – 100 µA
25°C
4.98
4.98
25°C
4.9 4.93
4.9 4.93
V
Full range 4.7
4.7
IO = – 200 µA
25°C
4.8 4.86
4.8 4.86
VIC = 0,
IO = 50 µA
25°C
– 4.99
– 4.99
25°C – 4.85 – 4.91
– 4.85 – 4.91
VOM –
Maximum negative
peak output voltage
VIC = 0,
IO = 500 µA Full range – 4.85
– 4.85
V
VIC = 0,
m IO = 4 A
25°C
Full range
–4
– 3.8
– 4.3
– 4 – 4.3
– 3.8
AVD
Large-signal differential
voltage amplification
rid
Differential input
resistance
VO = ± 4 V
RL = 50 kΩ
RL = 1 MΩ
25°C
Full range
25°C
25°C
40 150
10
3000
1012
40 150
10
3000
1012
V/mV
Ω
ric
Common-mode input
resistance
25°C
1012
1012
Ω
cic
Common-mode input
capacitance
f = 10 kHz, P package
25°C
8
8
pF
zo
Closed-loop output
impedance
f = 25 kHz, AV = 10
25°C
190
190
Ω
CMRR
Common-mode
rejection ratio
VIC = – 5 V to 2.7 V,
25°C
75
88
VO = 0,
RS = 50 Ω Full range
75
75
88
dB
75
kSVR
Supply-voltage rejection
ratio (∆VDD ± /∆VIO)
VDD = 4.4 V to 16 V,
VIC = VDD /2, No load
25°C
80
95
Full range
80
80
95
dB
80
IDD Supply current
VO = 2.5 V, No load
25°C
Full range
80 125
150
80 125
µA
150
† Full range is – 40°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 500 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
16
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265