English
Language : 

TLC227X_07 Datasheet, PDF (14/67 Pages) Texas Instruments – Advanced LinCMOS RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
TLC227x, TLC227xA
ą
Advanced LinCMOS RAILĆTOĆRAIL
OPERATIONAL AMPLIFIERS
SLOS190G − FEBRUARY 1997 − REVISED MAY 2004
TLC2272I electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TLC2272I
TLC2272AI
TA†
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
300 2500
3000
300 950
µV
1500
αVIO
Temperature coefficient
of input offset voltage
25°C
to 85°C
2
2
µV/°C
Input offset voltage
long-term drift
(see Note 4)
VIC = 0 V,
VO = 0 V,
VDD ± = ± 2.5 V
RS = 50 Ω
25°C
25°C
0.002
0.5
60
0.002
0.5
µV/mo
60
IIO
Input offset current
−40°C to 85°C
150
150 pA
Full range
800
800
25°C
1
60
1
60
IIB
Input bias current
−40°C to 85°C
150
150 pA
Full range
800
800
VICR
Common-mode input
voltage
RS = 50 Ω,
|VIO | ≤ 5 mV
25°C
Full range
0 to 4
0 to
3.5
−0.3
to 4.2
0 to 4
0 to
3.5
−0.3
to 4.2
V
VOH
High-level output
voltage
IOH = − 20 µA
IOH = − 200 µA
IOH = − 1 mA
25°C
4.99
4.99
25°C
4.85 4.93
4.85 4.93
Full range
4.85
4.85
V
25°C
4.25 4.65
4.25 4.65
Full range
4.25
4.25
VOL
Low-level output
voltage
VIC = 2.5 V,
VIC = 2.5 V,
VIC = 2.5 V,
IOL = 50 µA
IOL = 500 µA
IOL = 5 mA
25°C
25°C
Full range
25°C
Full range
0.01
0.09 0.15
0.15
0.9 1.5
1.5
0.01
0.09 0.15
0.15
V
0.9 1.5
1.5
AVD
Large-signal differential
voltage amplification
VIC = 2.5 V,
VO = 1 V to 4 V
RL = 10 kه
RL = 1 mه
rid
Differential input
resistance
25°C
Full range
25°C
25°C
15
35
15
175
1012
15
35
15
175
1012
V/mV
Ω
ri
Common-mode input
resistance
25°C
1012
1012
Ω
ci
Common-mode input
capacitance
f = 10 kHz,
P package
25°C
8
8
pF
zo
Closed-loop output
impedance
f = 1 MHz,
AV = 10
25°C
140
140
Ω
CMRR
Common-mode
rejection ratio
VIC = 0 V to 2.7 V,
VO = 2.5 V,
RS = 50 Ω
25°C
Full range
70
75
70
70
75
dB
70
kSVR
Supply-voltage
rejection ratio
(∆VDD /∆VIO)
VDD = 4.4 V to 16 V,
VIC = VDD /2,
No load
25°C
Full range
80
95
80
80
95
dB
80
IDD
Supply current
VO = 2.5 V,
No load
25°C
Full range
2.2
3
3
2.2
3
mA
3
† Full range is − 40°C to 125°C.
‡ Referenced to 0 V
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
14
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265