English
Language : 

OPA2277-EP Datasheet, PDF (14/21 Pages) Texas Instruments – OPA2277-EP High-Precision, Low-Noise Operational Amplifier
OPA2277-EP
SBOS700 – DECEMBER 2014
www.ti.com
V+
R–∆R
V1
Load
Cell
R+∆R
V2
R+∆R
R–∆R
1/2
OPA2277
V–
V+
1/2
OPA2277
VOUT
=
(V1
–
V2)(1
+
R2
R1
)
R2
R1
V–
R2
R1
A. For integrated solution see: INA126, INA2126 (dual), INA125 (on-board reference), or INA122 (single-supply).
Figure 24. Load Cell Amplifier
9.2.3 Application Curves
At TJ = 25°C, VS = ±15 V, and RL = 2 kΩ. Figure 25 shows Change in input bias current versus power supply
voltage. Curve shows normalized change in bias current with respect to VS = ±10 V (+20 V). Typical IB may
range from –0.5 to 0.5 nA at VS = ±10 V. Figure 26 shows change in input bias current versus common-mode
voltage. Curve shows normalized change in bias current with respect to VCM = 0 V. Typical IB may range from
–0.5 to 0.5 nA at VCM = 0 V.
2.0
1.5
1.0
0.5
0.0
–0.5
VCM = 0 V
–1.0
–1.5
–2.0
0
5 10 15 20 25 30 35 40
Supply Voltage (V)
Figure 25. Change in Input Bias Current vs Power Supply
Voltage
2.0
1.5
1.0
VS = ±5 V
0.5
0.0
–0.5
–1.0
VS = ±15 V
–1.5
–2.0
–15
–10
–5
0
5
10
15
Common-Mode Voltage (V)
Figure 26. Change in Input Bias Current vs Common-Mode
Voltage
14