BQ27500 Datasheet, PDF (14/39 Pages) Texas Instruments – System-Side Impedance Track™ Fuel Gauge
bq27500
bq27501
System-Side Impedance Track™ Fuel Gauge
SLUS785 – SEPTEMBER 2007
www.ti.com
4.1.1.16 MaxLoadCurrent( ): 0x1e/0x1f
This read-only function returns a signed integer value, in units of mA, of the maximum load conditions.
The MaxLoadCurrent( ) is an adaptive measurement which is initially reported as the maximum load
current programmed in Initial Max Load Current. If the measured current is ever greater than Initial Max
Load Current, then MaxLoadCurrent( ) updates to the new current. MaxLoadCurrent( ) is reduced to the
average of the previous value and Initial Max Load Current whenever the battery is charged to full after
a previous discharge to an SOC less than 50%. This prevents the reported value from maintaining an
unusually high value.
4.1.1.17 MaxLoadTimeToEmpty( ): 0x20/0x21
This read-only function returns an unsigned integer value of the predicted remaining battery life at the
maximum load current discharge rate, in minutes. A value of 65535 indicates that the battery is not being
discharged.
4.1.1.18 AvailableEnergy( ): 0x22/0x23
This read-only function returns an unsigned integer value of the predicted charge or energy remaining in
the battery. The value is reported in units of mWh.
4.1.1.19 AveragePower( ): 0x24/0x25
This read-word function returns an unsigned integer value of the average power of the current discharge.
A value of 0 indicates that the battery is not being discharged. The value is reported in units of mW.
4.1.1.20 TimeToEmptyAtConstantPower( ): 0x26/0x27
This read-only function returns an unsigned integer value of the predicted remaining operating time if the
battery is discharged at the AveragePower( ) value in minutes. A value of 65535 indicates
AveragePower( ) = 0. The fuel gauge automatically updates TimeToEmptyatContantPower( ) based on the
AveragePower( ) value every 1s.
4.1.1.21 CycleCount( ): 0x2a/0x2b
This read-only function returns an unsigned integer value of the number of cycles the battery has
experienced with a range of 0 to 65535. One cycle occurs when accumulated discharge ≥ CC Threshold.
4.1.1.22 StateOfCharge( ): 0x2c/0x2d
This read-only function returns an unsigned integer value of the predicted remaining battery capacity
expressed as a percentage of FullChargeCapacity( ), with a range of 0 to 100%.
4.1.2 EXTENDED DATA COMMANDS
Extended commands offer additional functionality beyond the standard set of commands. They are used in
the same manner; however unlike standard commands, extended commands are not limited to 2-byte
words. The number of commands bytes for a given extended command ranges in size from single to
multiple bytes, as specified in Table 4-5. For details on the SEALED and UNSEALED states, see
Section 4.4 Access Modes.
NAME
Reserved
DesignCapacity( )
DataFlashClass( ) (2)
DataFlashBlock( ) (2)
Authenticate( )/BlockData( )
AuthenticateCheckSum( )/BlockData( )
Table 4-5. Extended Data Commands
RSVD
DCAP
DFCLS
DFBLK
A/DF
ACKS/DFD
COMMAND
CODE
0x34...0x3b
0x3c / 0x3d
0x3e
0x3f
0x40…0x53
0x54
UNITS
N/A
mAh
N/A
N/A
N/A
N/A
SEALED
ACCESS(1) (2)
R
R
N/A
R/W
R/W
R/W
UNSEALED
ACCESS (1) (2)
R
R
R/W
R/W
R/W
R/W
(1) SEALED and UNSEALED states are entered via commands to CNTL 0x00/0x01.
(2) In sealed mode, data flash CANNOT be accessed through commands 0x3e and 0x3f.
14
GENERAL DESCRIPTION
Submit Documentation Feedback