English
Language : 

LMC6082IMX Datasheet, PDF (13/22 Pages) Texas Instruments – LMC6082 Precision CMOS Dual Operational Amplifier
www.ti.com
LMC6082
SNOS630D – AUGUST 2000 – REVISED MARCH 2013
(Input pins are lifted out of PC board and soldered directly to components. All other pins connected to PC board).
Figure 30. Air Wiring
Typical Single-Supply Applications
(V+ = 5.0 VDC)
The extremely high input impedance, and low power consumption, of the LMC6082 make it ideal for applications
that require battery-powered instrumentation amplifiers. Examples of these types of applications are hand-held
pH probes, analytic medical instruments, magnetic field detectors, gas detectors, and silicon based pressure
transducers.
Figure 31 shows an instrumentation amplifier that features high differential and common mode input resistance
(>1014Ω), 0.01% gain accuracy at AV = 1000, excellent CMRR with 1 kΩ imbalance in bridge source resistance.
Input current is less than 100 fA and offset drift is less than 2.5 μV/°C. R2 provides a simple means of adjusting
gain over a wide range without degrading CMRR. R7 is an initial trim used to maximize CMRR without using
super precision matched resistors. For good CMRR over temperature, low drift resistors should be used.
If R1 = R5, R3 = R6, and R4 = R7; then
∴AV ≈ 100 for circuit shown (R2 = 9.822k).
Figure 31. Instrumentation Amplifier
Figure 32. Low-Leakage Sample and Hold
Copyright © 2000–2013, Texas Instruments Incorporated
Submit Documentation Feedback
13
Product Folder Links: LMC6082